201375
<location>Topology: Actual topology, duplicate connection between two components
Message value:
Preliminary component number: %1, component class: %2, connection number: %3
Drive object:
All objects
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
When detecting the actual topology, a ring-type connection was detected.
Fault value (r0949, interpret hexadecimal):
ccbbaaaa hex:
cc = connection number
bb = component class
aaaa = preliminary component number of a component included in the ring
Component class:
1: Control Unit.
2: Motor Module.
3: Line Module.
4: Sensor Module (SM).
5: Voltage Sensing Module (VSM).
6: Terminal Module (TM).
7: DRIVE-CLiQ Hub Module.
8: Controller Extension 32 (CX32, NX10, NX15).
49: DRIVE-CLiQ components (non-listed components).
50: Option Slot (e.g. Terminal Board 30).
60: Encoder (e.g. EnDat).
70: Motor with DRIVE-CLiQ.
Component type:
Precise designation within a component class (e.g. "SMC20").
Connection number:
Consecutive numbers, starting from zero, of the appropriate connection or slot (e.g. DRIVE-CLiQ connection X100 on
the Control Unit has the connection number 0).
Remedy:
Output the fault value and remove the specified connection.
Note:
Under "Topology --> Topology view" the commissioning software offers improved diagnostics capability (e.g. setpoint/
actual value comparison).
201380
<location>Topology: Actual topology, defective EEPROM
Message value:
Preliminary component number: %1
Drive object:
All objects
Reaction:
NONE
Acknowledge:
POWER ON
Cause:
When detecting the actual topology, a component with a defective EEPROM was detected.
Fault value (r0949, interpret hexadecimal):
bbbbaaaa hex:
aaaa = preliminary component number of the defective components
Remedy:
Output the fault value and remove the defected component.