Block %2 No Memory Left For Tool/Magazine Data; Block %2 No Memory Left - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

17001
[Channel %1: ] Block %2 no memory left for tool/magazine data
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The number of the following tool/magazine data variables in the NC is specified using machine data:
- Number of tools + number of grinding data blocks: MD18082 $MN_MM_NUM_TOOL
- Number of cutting edges: MD18100 $MN_MM_NUM_CUTTING_EDGES_IN_TOA
Tools, grinding data blocks, cutting edges can be used independently of the tool management.
The memory for the following data is available only if the corresponding bit has been set in MD18080
$MN_MM_TOOL_MANAGEMENT_MASK.
- Number of monitoring data blocks: MD18100 $MN_MM_NUM_CUTTING_EDGES_IN_TOA
- Number of magazines: MD18084 $MN_MM_NUM_MAGAZINE
- Number of magazine locations: MD18086 $MN_MM_NUM_MAGAZINE_LOCATION
The following variable is determined by the software configuration: Number of magazine spacing data blocks: P2 per-
mits 32 such spacing data blocks.
Definition:
- 'Grinding data blocks': Grinding data can be defined for a tool of type 400 to 499. A data block of this type occupies
as much additional memory as that provided for a cutting edge.
- 'Monitoring data blocks': Each cutting edge of a tool can be supplemented with monitoring data.
- If the alarm occurs while writing one of the parameters $TC_MDP1/$TC_MDP2/$TC_MLSR,
check whether machine data MD18077 $MN_MM_NUM_DIST_REL_PER_MAGLOC /
MD18076$MN_MM_NUM_LOCS_WITH_DISTANCE has been set correctly.
MD18077 $MN_MM_NUM_DIST_REL_PER_MAGLOC defines the number of different Index1 statements that may
be made for an Index2 value.
MD18076 $MN_MM_NUM_LOCS_WITH_DISTANCE defines the number of different buffer locations that may be
named in Index2.
If a multitool is to be generated or its locations, the alarm indicates that either more multitools need to be generated
than are permitted by the setting of MD18083 $MN_MM_NUM_MULTITOOL or, if the alarm occurs when the multitool
locations are being generated, that more multitool locations need to be generated than is permitted by the setting of
MD18085 $MN_MM_NUM_MULTITOOL_LOCATIONS.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Modify machine data
- Modify NC program, i.e. reduce number of rejected variable.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17010
[Channel %1: ] Block %2 no memory left
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
When executing/reading files from the active working memory, it was found that there is not enough memory space
(e.g. for large multidimensional arrays or when creating tool offset memory).
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Make arrays smaller or make more memory space avail-
able for memory management of subroutine calls, tool offsets and user variables (machine data MM_...).
See /FB/, S7 Memory Configuration
Program
Clear alarm with the RESET key. Restart part program