Remedy:
Please inform the authorized personnel/service department.
The following axis/spindle was not able to follow the leading axis(axes)/spindle(s).
Program
Clear alarm with the Delete key or NC START.
Continuation:
22030
[Channel %1: ] Block %2 following spindle %3 Impermissible programming
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Spindle
Definitions:
With synchronous spindle-VV-coupling an additional motion for the following spindle can only be programmed with
M3, M4, M5 and S... The paths created by specified positions cannot be maintained safely for a velocity coupling,
especially if a position control is missing. If dimensional accuracy or reproducibility are not important, the alarm can
be suppressed with MD11410 $MN_SUPPRESS_ALARM_MASK Bit27 = 1.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Use synchronous spindle-DV-coupling or program direction of rotation and speed.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
22033
[Channel %1: ] Block %2 Axis/spindle %3 'Correct synchronism' diagnostics %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis/spindle number
%4 = Diagnostics
Definitions:
The following situation occurred during 'Correct synchronism':
- Diagnosis 1: An existing override motion is terminated on key reset.
- Diagnosis 2: The override motion has been deleted.
- Diagnosis 3: Writing of override value not allowed. Synchronism override is deleted.
- Diagnosis 4: Override motion is stopped temporarily (e.g. G74 reference point approach)
- Diagnosis 5: Delay of override motion: acceleration capacity used up by other motions.
- Diagnosis 6: Delay of override motion: velocity used up by other motions.
- Diagnosis 7: Delay of override motion: the maximum speed is limited to 0. System variable
$AC_SMAXVELO_INFO[n] shows the reason for this.
- Diagnosis 8: Delay of override motion: the maximum acceleration capacity is limited to 0. $AC_SMAXACC_INFO[n]
shows the reason for this.
MD11411 $MN_ENABLE_ALARM_MASK activates this alarm:
- Bit 9 = 1 for diagnosis 1 to 6
- Bit 12 = 1 for diagnosis 7 to 8
Reaction:
Alarm display.
Remedy:
Deactivate the alarm with MD 11411 $MN_ENABLE_ALARM_MASK Bit9 = 0 or Bit12 = 0.
Program
Clear alarm with the Delete key or NC START.
Continuation:
22035
[Channel %1: ] Block %2 following axis/spindle %3 unable to determine the offset value
(reason %4).
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Following axis/spindle number
%4 = Reason