Block %2 Illegal Program Path %3; Block %2 Invalid Default Parameter In Subroutine Call; Block %2 Program %3 Not Existing Or Will Be Edited - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
14009
[Channel %1: ] Block %2 illegal program path %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program path
Definitions:
The part program command CALLPATH was called with a parameter (program path) referring to a directory which
does not exist in the file system of the NCK.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Modify the CALLPATH instruction such that the parameter contains the complete path name of the loaded directory.
- Load the programmed directory in the file system of the NCK.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14010
[Channel %1: ] Block %2 invalid default parameter in subroutine call
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In a subroutine call with parameter transfer, parameters have been omitted that cannot be replaced by default param-
eters (call-by-reference parameters or parameters of type AXIS. The other missing parameters are defaulted with the
value 0 or with the unit frame in the case of frames).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
The missing parameters must be provided with values in the subroutine call.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14011
[Channel %1: ] Block %2 program %3 not existing or will be edited
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program name
Definitions:
A subroutine call was aborted because the called subroutine could not be opened.
The subroutine call can be executed via
- subroutine designator
- CALL / PCALL / MCALL command
- SETINT command
- M/T function replacement
- event-driven program calls (PROG_EVENT)
- selection of a PLC ASUB via PI "_N_ASUP__" and/or FB-4
- calling a PLC ASUB via interrupt interface (FC-9)
There are various reasons for the alarm:
- the subroutine is not in the parts program memory the subroutine
- the subroutine is not in the search path (selected directory, _N_SPF_DIR or cycle directories _N_CUS_DIR,
_N_CMA_DIR, _N_CST_DIR
- the subroutine has not been released or is being edited
- faulty absolute path name in subroutine call:
Examples of complete path names: /_N_directoryName_DIR/_N_programmName_SPF or /_N_WKS_DIR/
_N_wpdName_WPD/_N_programmName_SPF. directoryName: MPF, SPF, CUS, CMA, CST (predefined directo-
ries). wpdName: application-specific designator for workpiece directories (max. of 24 signs). programmName: Name
of subroutine (max. of 24 signs)
- A reload buffer for executing from external was called as subroutine.
Note: Unknown designators (string) found in the parts program line by themselves, are interpreted as subroutine calls.