Block %2: Grinding Wheel Diameter Worn Down; Block %2: Width Of Grinding Wheel Worn Down; Block %2: Dresser %4, Wear Limit Length 1 Reached; Block %2: Dresser %4, Wear Limit Length 2 Reached - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
61544
[Channel %1: ] Block %2: Grinding wheel diameter worn down
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE438
Remedy:
New grinding wheel required, or check limit values in the grinding wheel data
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61545
[Channel %1: ] Block %2: Width of grinding wheel worn down
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE438
Remedy:
New grinding wheel required, or check limit values in the grinding wheel data
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61546
[Channel %1: ] Block %2: Dresser %4, wear limit length 1 reached
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE438
Remedy:
New dresser required, or check limit values of dresser
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61547
[Channel %1: ] Block %2: Dresser %4, wear limit length 2 reached
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE438
Remedy:
New dresser required, or check limit values of dresser
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61548
[Channel %1: ] Block %2: Dresser %4, wear limit length 3 reached
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE438
Remedy:
New dresser required, or check limit values of dresser
Program
Clear alarm with the RESET key. Restart part program
Continuation:
460
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents