Nc Code Identifier %1 Cannot Be Reconfigured To %2; Standard Machine Data Loaded (%1, %2, %3, %4); Backup Data Loaded - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

4050

NC code identifier %1 cannot be reconfigured to %2

Parameters:
%1 = String: Old identifier
%2 = String: New identifier
Definitions:
Renaming of an NC code was not possible for one of the following reasons:
- The old identifier does not exist
- The new identifier lies in another type range.
NC codes/keywords can be reconfigured via machine data as long as the type range is not abandoned.
Type 1: "real" G codes: G02, G17, G33, G64, ...
Type 2: named G codes: ASPLINE, BRISK, TRANS, ...
Type 3: settable addresses: X, Y, A1, A2, I, J, K, ALF, MEAS, ...
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Correct MD10712 $MN_NC_USER_CODE_CONF_NAME_TAB (protection level 1).
The list must be built up as follows:
Even address: Identifier to be modified.
Following odd address: New identifier
e.g.: $MN_NC_USER_CODE_CONF_NAME_TAB [10] = "ROT"
$MN_NC_USER_CODE_CONF_NAME_TAB [11] = " "
clears the ROT function from the control
Program
Switch control OFF - ON.
Continuation:
4060

Standard machine data loaded (%1, %2, %3, %4)

Parameters:
%1 = Identifier 1
%2 = Identifier 2
%3 = Identifier 3
%4 = Identifier 4
Definitions:
The standard MD were loaded because
- a cold start was requested or
- the MD buffer voltage failed or
- an initialization was requested for loading the standard machine data (MD11200 $MN_INIT_MD).
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department. After automatically loading the standard MDs, the individ-
ual MDs must be entered or loaded in the relevant system.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4062

Backup data loaded

Definitions:
The user data saved in the flash memory are loaded to the SRAM.
Reaction:
Alarm display.
Remedy:
Load specific machine data again.
Program
Clear alarm with the RESET key. Restart part program