Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Do not use rapid interrupt inputs or contact the machine
manufacturer with a view to retrofitting this option!
Program
Clear alarm with the RESET key. Restart part program
Continuation:
8010

Option 'activation of more than %1 axes' not set

Parameters:
%1 = Number of axes
Definitions:
More machine axes have been defined through the MD20070 $MC_AXCONF_MACHAX_USED than are allowed in
the system.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. The sum of all axes that have been configured using the
channel-specific MD20070 $MC_AXCONF_MACHAX_USED must not exceed the maximum number of axes (depen-
dent upon the configuration -> option, basic version: 4 axes).
Please also observe the information relating to the definition of auxiliary axes/spindles.
Program
Switch control OFF - ON.
Continuation:
8024

Option 'Activation of more than %1 magazines' not set

Parameters:
%1 = Number of permissible magazines
Definitions:
The option for activating multiple magazines is not set
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Buy option
- Reduce the number of magazines (MD18084 $MN_MM_NUM_MAGAZINE)
Program
Switch control OFF - ON.
Continuation:
8025

[Channel %1: ] Option 'Advanced Surface' not set

Parameters:
%1 = Channel number
Definitions:
The option for 'Advanced Surface' functionality is not set.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Purchase option
- Reset the activation of 'Advanced Surface' functionality (MD20606 $MC_PREPDYN_SMOOTHING_ON and/or
MD20443 $MC_LOOKAH_FFORM)
Program
Switch control OFF - ON.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
67