Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17070
[Channel %1: ] Block %2 data is write-protected
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An attempt was made to write into a write-protected variable (e.g. a system variable). Safety Integrated: Safety system
variables can only be written into via the safety SPL program.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17071
[Channel %1: ] Block %2 data read-protected
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An attempt has been made to read a read-protected variable (e.g. a system variable).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please set the corresponding access right or modify the part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17080
[Channel %1: ] Block %2 %3 value below lower limit
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = MD
Definitions:
An attempt was made to write into a machine data with a value smaller than the defined lower limit.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Determine the input limits of the machine data and assign
a value within these limits.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17090
[Channel %1: ] Block %2 %3 value exceeds upper limit
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = MD
Definitions:
An attempt was made to write into a machine data with a value greater than the defined upper limit.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.