16793
[Channel %1: ] Block %2 coupling of axis %3 prohibits transformation change
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
The specified axis is a slave axis in a transformation grouping. When the coupling is switched on, the transformation
cannot be changed to another one.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program. Switch off coupling(s) of this axis before changing transformation or do not change the transfor-
mation.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16794
[Channel %1: ] Block %2 coupling of axis/spindle %3 prohibits reference point
approach
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
The specified axis is a (gantry) slave axis and cannot therefore approach the reference point.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program. Switch off coupling(s) of this axis before reference point approach or do not reference. A gantry
slave axis cannot reference for itself.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16795
[Channel %1: ] Block %2 string cannot be interpreted
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A coupling has been switched on in which a non-interpretable string has been written (e.g. block change behavior).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16796
[Channel %1: ] Block %2 coupling not defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A coupling is to be switched the parameters of which have neither been programmed nor configured.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Correct NC part program or MD, program the coupling
with COUPDEF or configure by means of MD.
Alarms