Cutter Radius Too Small; Calculation Has Been Cancelled; Combination Of Centering/Predrilling And Spigot Not Allowed - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

61915
%[[Channel %1: ] Block %2: %]Cutter radius too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63, CYCLE64
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check the radius of the milling cutter in tool management
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61916
%[[Channel %1: ] Block %2: %]Calculation has been cancelled
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63, CYCLE64
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Calculation has been cancelled by PI service; please try again
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61917
%[[Channel %1: ] Block %2: %]Combination of centering/predrilling and spigot not
allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Machining of spigot in conjunction with predrilling/centering not allowed!
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61918
%[[Channel %1: ] Block %2: %]Cut. radius for residual mach. must be smaller than cut.
radius for ref. tool
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
483

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d