NCK alarms
4077

New value %1 of MD %2 not set. Requested %3 bytes too much %4 memory.

Parameters:
%1 = New value of machine data
%2 = Machine data number
%3 = Number of bytes requested that exceeded availability
%4 = Type of memory
Definitions:
An attempt was made to enter a new value in the specified memory configuration machine data. It was not possible
to modify the value, as this would have cleared the contents of the user memory. This was because the memory
requested exceeded the available capacity.
The third parameter specifies the number of bytes by which the maximum user memory was exceeded.
The fourth parameter specifies the type of memory whose limit was exceeded.
- "D" stands for dynamic or non-buffered user memory (this is where, for example, the LUD variables are stored and
the interpolation buffer size is entered). The capacity of this memory type is defined by the current memory configura-
tion and the value in MD18210 $MN_MM_USER_MEM_DYNAMIC.
- "S" stands for static or buffered user memory (this is where part programs, offset data, R parameters, tool data, etc.
are stored). This memory type is defined by the current memory configuration and the value in MD18230
$MN_MM_USER_MEM_BUFFERED.
- "iS" stands for internal static or buffered user memory. This memory type is defined by the current memory configu-
ration (not settable). A few NCK functions use this memory.
Reaction:
Alarm display.
Remedy:
If the modification was unintentional, ignore the error message and continue. The alarm has no negative effects. The
remedy depends on the access right and the current memory configuration of the NCK:
- The intended change is not possible -> Try again with a smaller value. Observe the change in the number of bytes.
- Is it possible to expand the memory? This option depends on the model in use. (Not possible if parameter 4 equals
"iS").
- The NCK user memory may have been set smaller than it could be. With the appropriate access authorization, the
machine data (see above) can be changed.
- If parameter 4 equals "iS" and no synchronous actions are used, then MD18232
$MN_MM_ACTFILESYS_LOG_FILE_MEM[2] = 0 can be set. Otherwise the desired machine data change cannot be
made.
Program
Clear alarm with the Delete key or NC START.
Continuation:
4080

Incorrect configuration of indexing axis in MD %1

Parameters:
%1 = String: MD identifier
Definitions:
The assignment of a position table to an indexing axis or the contents of a position table contains an error, or the length
of a position table has been parameterized with 0.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. 3 MD identifiers are output, depending on the type of
error.
1. MD30500 $MA_INDEX_AX_ASSIGN_POS_TAB: the error is due to multiple assignment of a position table
MD10910 $MN_INDEX_AX_POS_TAB_1 or MD10930 $MN_INDEX_AX_POS_TAB_2) to axes with different types
(linear/rotary axis).
2. MD10910 $MN_INDEX_AX_POS_TAB_1 or MD10930 $MN_INDEX_AX_POS_TAB_2: the contents of the dis-
played tables are incorrect.
- The entered positions must be arranged in increasing size.
- A particular position must not be set more than once.
- If the table is assigned to one or several modulo axes, then the contents must be within the 0 to < 360 degree range.
3. MD10900 $MN_INDEX_AX_LENGTH_POS_TAB_1 or MD10920 $MN_INDEX_AX_LENGTH_POS_TAB_2: the
length of the displayed position table n was specified with 0.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
28
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms