Technology Cycle Programmed With Too Many Parameters; Block %2 Combine Oscill And Posp During Oscillation With Infeedmotion; Block %2 Error In End Point Of Circle - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14028
[Channel %1: ] Block %2 motion-synchronous action: Technology cycle programmed
with too many parameters
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Maximum number of transfer parameters for one technology cycle exceeded.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Change technology cycle
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14030
[Channel %1: ] Block %2 combine OSCILL and POSP during oscillation with
infeedmotion
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
When oscillating controlled by synchronized actions, the assignment of oscillating and infeed axis (OSCILL) as well
as the definition of the infeed (POSP) must be carried out in one NC block.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14040
[Channel %1: ] Block %2 error in end point of circle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In circular interpolation, either the circle radii for the initial point and the end point are further apart, or the circle center
points are further apart, than specified in the machine data.
1. In circle radius programming the starting and end points are identical, thus the circle position is not determined by
starting and end points.
2. Radii: The NCK calculates from the present start point and the other programmed circle parameters the radii for the
start and the end point.
An alarm message is issued if the difference between the circle radii is either
- greater than the value in the MD21000 $MC_CIRCLE_ERROR_CONST (for small radii, if the programmed radius is
smaller than the quotient of the machine data MD21000 $MC_CIRCLE_ERROR_CONST divided by MD21010
$MC_CIRCLE_ERROR_FACTOR), or
- greater than the programmed radius multiplied by the MD21000 $MC_CIRCLE_ERROR_FACTOR (for large radii,
if the programmed radius is greater than the quotient of the machine data MD21000 $MC_CIRCLE_ERROR_CONST
divided by MD21000 $MC_CIRCLE_ERROR_FACTOR).
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
147

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents