Block %2 File Requested During Block Search Is Not Available; Block %2 Invalid Block Search Command; Block %2 Invalid Block Number As Search Target; Block %2 Invalid Label As Search Target - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
Reaction:
Alarm display.
Remedy:
Enter only positive number of passes within the range of values.
Program
Clear alarm with the Delete key or NC START.
Continuation:
15310
[Channel %1: ] Block %2 file requested during block search is not available
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
During block search, a target has been specified with a program that has not been loaded.
Reaction:
Alarm display.
Remedy:
Correct the specified search target accordingly or reload the file.
Program
Clear alarm with the Delete key or NC START.
Continuation:
15320
[Channel %1: ] Block %2 invalid block search command
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The block search command (type of search target) is smaller than 1 or greater than 5. It is entered in column type of
the block search window. The following block search orders are allowed.
Type Meaning
1 Search for block number
2 Search for label
3 Search for string
4 Search for program name
5 Search for line number in a file
Reaction:
Alarm display.
Remedy:
Modify the block search command.
Program
Clear alarm with the Delete key or NC START.
Continuation:
15330
[Channel %1: ] Block %2 invalid block number as search target
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Syntax error! Positive integers are allowed as block numbers. Block numbers must be preceded by ":" and subblocks
by an "N".
Reaction:
Alarm display.
Remedy:
Repeat the input with corrected block number.
Program
Clear alarm with the Delete key or NC START.
Continuation:
15340
[Channel %1: ] Block %2 invalid label as search target
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Syntax error! A label must have at least 2 but no more than 32 characters, and the first two characters must be alpha-
betic or underscore characters. Labels must be concluded with a colon.
Reaction:
Alarm display.
212
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d