Parameter %4 Incorrectly Defined For Tool Monitoring In Cycles; Block %2: Error In Function Tool Monitoring In Cycles; Block %2: Tool Cannot Be Aligned - Error Code: %4 - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
61137
[Channel %1: ] Block %2: swiveling and parallel axes cycle are mutually exclusive
because of workpiece reference $P_WPFRAME
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE69.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61138
[Channel %1: ] Block %2: parameter %4 incorrectly defined for tool monitoring in
cycles
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61139
[Channel %1: ] Block %2: error in function Tool monitoring in cycles
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE69.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61150
[Channel %1: ] Block %2: Tool cannot be aligned --> error code: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE800.
Remedy:
Causes of error:
1st error code = A -> only new swivel plane permitted, see parameter _ST
394
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents