NCK alarms
61506
[Channel %1: ] Block %2: infeed path < 1mm
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE420
Remedy:
Increase infeed path
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61507
[Channel %1: ] Block %2: safety clearance < 1mm
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61508
[Channel %1: ] Block %2: Incorrect default setting for shoulder position
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61509
[Channel %1: ] Block %2: Incorrect default setting for dresser position
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61510
[Channel %1: ] Block %2: Test run feed is active
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycles: CYCLE410, CYCLE411, CYCLE413, CYCLE415,
CYCLE420
Remedy:
Switch off test run feed
Program
Clear alarm with the RESET key. Restart part program
Continuation:
454
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0