NCK alarms
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Delete or unload files
MD18270: $MN_MM_NUM_SUBDIR_PER_DIR, MD18280: $MN_MM_NUM_FILES_PER_DIR or MD18320: Check
$MN_MM_NUM_FILES_IN_FILESYSTEM and increase if necessary.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61358
[Channel %1: ] Block %2: Error during recording
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE106.
Internal error
Remedy:
Call the hotline!
61359
[Channel %1: ] Block %2: - continue with RESET
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE106.
Internal error
Remedy:
Call the hotline!
61360
[Channel %1: ] Block %2: Log job undefined - continue with RESET
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycle: CYCLE106.
Cycle CYCLE106 was called by an incorrect parameter.
Remedy:
Check cycle call for CYCLE106, specifically the call parameter.
61361
[Channel %1: ] Block %2: Variable cannot be recorded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE105.
The value specified in _PROTVAL[] cannot be logged.
Remedy:
Check parameter _PROTVAL[].
61362
[Channel %1: ] Block %2: Cycle118: No. of values too large
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE118.
4th parameter for CYCLE118 is larger than 10.
Remedy:
Reduce the 4th parameter (PAR4) of CYCLE118.
442
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms