Remedy:
- Check parameter for plane infeed
- for G17: DXY
- for G18: DZX
- for G19: DYZ
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61946
%[[Channel %1: ] Block %2: %]Island contour existing twice
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63, CYCLE64
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Delete double island contour
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61947
%[[Channel %1: ] Block %2: %]Spigot contour existing twice
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63, CYCLE64
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Delete double spigot contour
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61948
%[[Channel %1: ] Block %2: %]No material available for machining
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63, CYCLE64
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check programming of the contours
Program
Clear alarm with the RESET key. Restart part program
Continuation:
Alarms