NCK alarms
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program tool (T).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61010
[Channel %1: ] Block %2: Finishing allowance too large
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The finishing allowance for the base is greater than the total depth. Alarm triggered by following cycle: CYCLE72.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Reduce finishing allowance.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61011
[Channel %1: ] Block %2: Scaling not permissible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A scale factor is active which is illegal for this cycle. Alarm triggered by following cycles: CYCLE71, CYCLE72.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify scale factor.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61012
%[[Channel %1: ] Block %2: %]Different scaling in planes
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63, CYCLE64, CYCLE76, CYCLE77.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
372
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms