NCK alarms
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check feed type
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61241
[Channel %1: ] Block %2: Retraction plane not defined for this machining direction
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No retraction plane has been defined for the selected machining direction.
Alarm triggered by following cycles: F_SP_RP, F_SP_RPT.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Define the missing retraction plane.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61242
[Channel %1: ] Block %2: Wrong machine direction
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The machining direction has been specified incorrectly.
Alarm triggered by following cycles: F_DR, F_DR_PEC, F_DR_REA, F_DR_SIN, F_DR_TAP, F_DRILL, F_DRILLC,
F_DRILLD, F_DRM_DR, F_DRM_PE, F_DRM_RE, F_DRM_SI, F_DRM_TA, F_MI_CON, F_MI_EDG, F_MI_TR,
F_MI_TXT, F_MIM_TR, F_PI_CIR, F_PI_REC, F_PO_CIR, F_PO_REC, F_SL_CIR, F_SL_LON, F_TAP.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check the programmed machining direction.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61243
[Channel %1: ] Block %2: Correct tool change point, tool tip in
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The tool change point must be situated so far outside the retraction area that no tool protrudes into the retraction area
on turret swivelling.
Alarm triggered by following cycle: F_SP_RP
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Specify another tool change point.
Program
Clear alarm with the RESET key. Restart part program
Continuation: