[Channel %1:] Invalid M Auxiliary Function Number In %2%3, Md Reset; M Auxiliary Function Number %2 Used Several Times (%3 And %4); Illegally Predefined Auxiliary Function In %2%3, Md Reset - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

4182
[Channel %1: ] Invalid M auxiliary function number in %2%3, MD reset
Parameters:
%1 = Channel number
%2 = MD identifier
%3 = If required, MD index
Definitions:
In the specified machine data, a number has been specified for the configuration of an M function which is occupied
by the system, and cannot be used for an assignment. (M0 to M5, M17, M30, M40 to M45 and also M98, M99 with
applied ISO dialect). The value set by the user has been reset to the default value by the system.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Configure an M function in the specified machine data which is not occupied by the system (M0 to M5, M17, M30, M40
to M45 and also M98, M99 with applied ISO dialect).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4183
[Channel %1: ] M auxiliary function number %2 used several times (%3 and %4)
Parameters:
%1 = Channel number
%2 = M auxiliary function number
%3 = MD identifier
%4 = MD identifier
Definitions:
In the specified machine data, a number has been used several times for the configuration of an M function.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Check the specified machine data and create a unique assignment of M auxiliary function numbers.
Program
Switch control OFF - ON.
Continuation:
4184
[Channel %1: ] Illegally predefined auxiliary function in %2%3, MD reset
Parameters:
%1 = Channel number
%2 = MD identifier
%3 = If required, MD index
Definitions:
In the specified machine data, a predefined auxiliary function has been illegally configured.
The value set by the user has been reset to the default value by the system.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Configure a valid value in the specified machine data.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents