Chapter 1 Overview

1.7 Error Message Format

1.7
Error Message Format
This section explains the CLI error messages format. When the CLI command ends normally, there is no output
on the terminal and the CLI prompt is returned to the next line. If an error occurs, an error message is
displayed. For further details of the error messages, refer to
827).
Error: E0019 Inconsistent parameter.
A
A:
Error message number (fixed 4 digits)
B:
Error message (human-readable message)
C:
Internal error code (fixed 4 digits + hyphen + fixed 4 digits)
D:
Details (the specified parameters, etc.)
Note that there are messages without an error message number. The location of the error is indicated by a
circumflex (^). This will display where there is a syntax error. Check the input parameters and the error
message as indicated by the circumflex (^).
The following are examples.
CLI> create raid-group -a
Error: Missing parameter data
CLI> show disks -de 1 -de 2
1.8

Multiple Sessions

A maximum of 16 CLI sessions can run on a single system simultaneously (including accesses with the
Software role). A session for an exclusive resource may conflict with a GUI session or another CLI session.
When a resource is locked by exclusive access control, the command terminates with an error message. If this
occurs, wait until the GUI session or another CLI session that uses the locked resource completes, and then
execute the command again. Resources can be forcibly released by using the "set clienv-force-unlock"
command. This is useful when a terminal is suddenly disconnected or unexpected errors occur.
B
[001C-0002] -disks 003
C
D
^
^
ETERNUS CLI User's Guide
Copyright 2014 FUJITSU LIMITED
"Appendix A Error Messages/Error Codes" (page
34
P2X0-1210-05ENZ0

Hide quick links: