Mitsubishi Electric MELSERVO MR-J2-A Product Specifications And Installation Manual page 120

Servo motors and servo amplifiers
Table of Contents

Advertisement

3.WIRING
(5) Analog input
Input impedance
10 ~ 12KΩ
Upper limit setting 2kΩ
2kΩ
(7) Source input interface
When using the input interface of source type, all DI-1 input signals are of source type.
Source output cannot be provided.
For use of internal power supply
(Note)
For a transistor
Approx. 5mA
TR
V
1.0V
CES
I
100µA
CEO
Note: This also applies to the use of the external power supply.
Servo amplifier
15VDC
P15R
VC‚ etc
Approx.
LG
10kΩ
SD
Servo amplifier
SG
R: Approx. 4.7kΩ
COM
SON, etc.
Switch
VDD
3– 35
(6) Analog output
Output ±10V
Max. 1mA
Servo amplifier
10kΩ
MO1
(MO2)
Reading in one or
both directions
LG
1mA meter
SD
For use of external power supply
Servo amplifier
SG
COM
Switch
SON, etc.
24VDC
200mA or more
A
R: Approx. 4.7kΩ
3