3.WIRING
4) Speed limit in torque control mode
a. Speed limit value and speed
The speed is limited to the limit value set in parameter No. 8 (internal speed limit 1) or the
value set in the applied voltage of the
analog speed limit (VLA). A relationship between the analog speed limit (VLA) applied
voltage and the servo motor speed is as in 3)a, (3) in this section.
b. Connection diagram
Generally connect as shown in Fig. 3-16. When a precision speed command is required,
refer to 3b, (3) in this section.
c. Speed selection 1 (SP1) and speed limit value
Use speed selection 1 (SP1) to select between the speed set to the internal speed limit 1
and the speed set to the analog speed limit (VLA) as indicated in Table 3-10.
When the internal speed limit 1 is used to command the speed, the speed does not vary
with the ambient temperature.
d. Limiting speed (VLC)
As in 3)d, (3) in this section.
5) Torque control in torque control mode
As in 1), (3) in this section.
6) Torque limit in torque control mode
As in 2), (3) in this section.
2kΩ
2kΩ
Japan Resistor
RRS10 or equivalent
Fig. 3-16 Connection Example
Table 3-10 SP1 and Speed Limit Value
Across SP1-SG
Open
Analog speed limit (VLA)
Short
Internal speed limit 1 (parameter No. 8)
Servo amplifier
SP1
SG
P15R
VLA
LG
SD
Speed Command Value
3– 30