ABB IRB 7600 Series Product Manual page 99

Hide thumbs Also See for IRB 7600 Series:
Table of Contents

Advertisement

Installation, fan
The procedure below details how to install the cooling fan on any of the motors,
axes 1-3 .
1
2
3
4
5
6
Separate cabling for axis 1 or 2
The figure below shows the cabling used only for the fan on axis 1 or 2.
xx0500002173
Product manual - IRB 7600
3HAC022033-001 Revision: V
Action
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
Prepare the fanbox for installation:
disassemble the two parts of the box by removing the
nine attachment screws
loosen the three tightening screws, to avoid damaging
the surfaces of the motor when fitting the fanbox
turn the connector to the correct position; axis 1:
groove pointing inwards, as shown in the figure
Cooling fan on page
are shown in the figure
page
96.
Temporarily lift the motor cabling out of the way of the current
motor to make room for the fanbox.
Fit the parts of the fanbox to the motor and reassemble with
the nine attachment screws.
Lift the box (axis 1) so that it does not rest directly on the
robot and secure the box with the three tightening screws,
using locking liquid. Tighten them properly so that the box
is firmly attached to the motor.
Install the cabling and make adjustments in RobotWare, as
described in the following procedures.
© Copyright 2007 - 2018 ABB. All rights reserved.
2 Installation and commissioning
2.5.11 Installation of cooling fan for motors (option)
97. Positions for axis 2 and 3
Location of cooling fans on
Continued
Note
Shown in the figure
Cool-
ing fan on page
97.
Continues on next page
99