Confirming A Nodeb Commissioning Task; Confirming An Enodeb Commissioning Task; Reference To The Gbts Commissioning Interface - Huawei 3900 Series Commissioning Manual

Multi-mode base station
Hide thumbs Also See for 3900 Series:
Table of Contents

Advertisement

3900 Series Multi-Mode Base Station
Commissioning Guide
l
----End

5.11.2 Confirming a NodeB Commissioning Task

This section describes how to confirm a NodeB commissioning task. After a NodeB passes the
service verification, the status of the NodeB commissioning task changes to Waiting for
Acknowledgement. You need to manually confirm that the commissioning is complete.
Context
If some alarms are still not cleared during the commissioning, it is recommended that you not
confirm the commissioning task. After you confirm the commissioning task, any alarm generated
during the commissioning cannot be viewed on the basis of a single NodeB on the Monitor tab
page. If any uncleared alarm exists during the commissioning, the alarm is reported again in the
Normal status.
Procedure
Step 1 Choose Configuration > Auto Deployment > NodeB Auto Deployment. The NodeB Auto
Deployment window is displayed.
Step 2 In the commissioning task list, select the commissioning task to be confirmed.
Step 3 Click
After the commissioning is complete, the M2000 performs the following operations:
l
l
----End

5.11.3 Confirming an eNodeB Commissioning Task

After the eNodeB health check is complete, the status of the commissioning task changes to
Awaiting_ack. In this case, you need to acknowledge the eNodeB commissioning.
Procedure
Step 1 On the M2000 client, choose Configuration > Auto Deployment > eNodeB Auto
Deployment. The eNodeB Auto Deployment tab page is displayed.
Step 2 Right-click the target commissioning task and choose Acknowledge from the shortcut menu.
The commissioning task is acknowledged.
----End

5.12 Reference to the GBTS Commissioning Interface

This section describes the interfaces and parameters for GBTS commissioning and facilitates
you to perform relevant operations for GBTS commissioning.
5.12.1 Interface Description: GBTS Commissioning
Issue 02 (2010-07-30)
Stop subscribing to the performance counters of the GBTS for service verification.
on the toolbar to confirm that the commissioning is complete.
Stop monitoring the alarms on the NodeB and its RNC.
Stop subscribing to the service verification performance counters of the NodeB.
Huawei Proprietary and Confidential