Parameter
RNC Name
NodeB ID
NodeB Name
NodeB ESN1
NodeB ESN2
NodeB TRANS IP
address
NodeB TRANS IP
Subnet mask
NodeB Interface IP
address
NodeB Interface IP
Subnet mask
Issue 02 (2010-07-30)
Description
Name of the RNC to which the NodeB belongs
This parameter can be optionally exported from the CME. It is not
configurable in the NodeB Auto Deployment window.
ID of the NodeB
This parameter must be exported from the CME. It is not configurable
in the NodeB Auto Deployment window.
Name of the NodeB
This parameter must be exported from the CME. It is not configurable
in the NodeB Auto Deployment window.
Electronic serial number (ESN) of the active main control board of a
NodeB (it must be exported from the CME if it is planned)
The ESN uniquely identifies one NodeB. The ESN is usually labeled
as the bar code on the main control board of the NodeB. The site
engineer should record the ESN before leaving the site, so as to assist
the commissioning engineer in the remote check on the site.
This parameter can be optionally exported from the CME. It is
configurable in the NodeB Auto Deployment window.
ESN of the standby main control board of the NodeB (it must be
exported from the CME if it is planned)
This parameter can be optionally exported from the CME. It is
configurable in the NodeB Auto Deployment window.
OM IP address of the NodeB configured at the RNC
This parameter must be exported from the CME. It is not configurable
in the NodeB Auto Deployment window.
OM IP subnet mask of the NodeB configured at the RNC
This parameter must be exported from the CME. It is not configurable
in the NodeB Auto Deployment window.
IP address of the port on the NodeB configured at the RNC (it must
be exported from the CME if the port type of the NodeB is set to ETH/
TRUNK)
This parameter can be optionally exported from the CME. It is not
configurable in the NodeB Auto Deployment window.
IP subnet mask of the port on the NodeB configured at the RNC (it
must be exported from the CME if the port type of the NodeB is set
to ETH/TRUNK)
This parameter can be optionally exported from the CME. It is not
configurable in the NodeB Auto Deployment window.