Upgrading The Enodeb Software And Downloading The Data Configuration File - Huawei 3900 Series Commissioning Manual

Multi-mode base station
Hide thumbs Also See for 3900 Series:
Table of Contents

Advertisement

3900 Series Multi-Mode Base Station
Commissioning Guide
l
----End
7.8 Upgrading the eNodeB Software and Downloading the
Data Configuration File
This section describes how to upgrade the eNodeB software and data configuration file on the
LMT. The upgraded eNodeB software and data configuration file take effect after the eNodeB
is automatically reset. The process for upgrading the eNodeB software and data configuration
file takes about 45 minutes.
Prerequisite
l
Issue 02 (2010-07-30)
3.
Type the user name and the password in the Name, Password, and Verify Code text
boxes. Set User Type to Local.
NOTE
By default, the user name and password is admin.
If the verify code is indistinct, click Change the verify code to change the verify code.
4.
Click Login. The LMT window is displayed.
NOTE
If the login fails due to entered incorrect information, click Reset and enter the correct information
in the Name, Password, and Verify Code text boxes. If the login failure persists, check the
connection between the LMT and the LMPT on the eNodeB
Logging in to the eNodeB through M2000
1.
Type the IP address for OM of the LMPT in the address box of the browser.
NOTE
Assume that the IE browser is used. Perform the following settings before typing the IP address:
1. Start the IE, and then choose Tools > Internet Options from the menu bar. On the
Connections tab page, click LAN Settings. In the displayed LAN Settings dialog box, under
Proxy server, select Use a proxy server for your LAN, and then type the IP address of the
M2000 in the Address box and set Port Number to 80.
2. Start the IE, and then choose Tools > Internet Options from the menu bar. On the Advanced
tab page, select Use HTTP1.1 through proxy connections under HTTP 1.1 settings.
2.
Click Go. The Local Maintenance Terminal dialog box is displayed, as shown in
Figure
7-31.
3.
Type the user name and the password in the Name, Password, and Verify Code text
boxes. Set User Type to EMS.
NOTE
The EMS user names and passwords are authorized by the M2000 server.
If the verify code is indistinct, click Change the verify code to change the verify code.
4.
Click Login. The LMT window is displayed.
NOTE
If the login fails due to entered incorrect information, click Reset and enter the correct information
in the Name, Password, and Verify Code text boxes. If the login failure persists, check the
connection between the LMT and the LMPT on the eNodeB
The LMT communicates properly with the eNodeB.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 Commissioning the MBTS by Using Local Maintenance
Terminal and M2000
7-39

Hide quick links:

Advertisement

Table of Contents
loading