Testing The Basic Services Of The Enodeb - Huawei 3900 Series Commissioning Manual

Multi-mode base station
Hide thumbs Also See for 3900 Series:
Table of Contents

Advertisement

3900 Series Multi-Mode Base Station
Commissioning Guide
Procedure
Step 1 Open the eNodeB commissioning report and view the health check report. Learn the running
status of the eNodeB.
Step 2 If the result of the eNodeB health check fails, check for active alarms and rectify the related
faults by referring to the eNodeB Alarm Reference. If all active alarms are cleared but the health
check still fails, contact Huawei for technical support.
----End

5.10 Testing the Basic Services of the eNodeB

This section describes how to test the basic services of the eNodeB.
Prerequisite
l
l
l
l
l
Procedure
l
l
l
l
Issue 02 (2010-07-30)
The eNodeB and the MME/S-GW are properly connected.
The negotiation data of the eNodeB to be commissioned is added to the MME/S-GW.
The testing UE is functional and is registered in the HSS.
The FTP server for testing the basic services is available.
The WWW server for testing the basic services is available.
Test the web page browsing service.
Testing Method Access the WWW server and browse the web pages through a UE.
Perform the test 20 times.
Expectation
Success rate > 95%. Web browsing is normal.
Test the file uploading service.
Testing Method Access the FTP server and upload files through a UE. Perform the
test 10 times.
Expectation
Success rate > 90%. The upload rate is stable.
Test the file downloading service.
Testing Method Access the FTP server and download files through a UE. Perform the
test 10 times.
Expectation
Success rate >90%. The download rate is stable.
Test the VoIP services.
Testing Method Use the testing UE to call another UE 20 times.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Commissioning the MBTS in GL or UL Mode on the
M2000
5-41