Table of Contents
About this Document
3
Table of Contents
6
1 Safety Information
11
General Safety
11
Personnel Requirements
14
Electrical Safety
14
Installation Environment Requirements
16
Mechanical Safety
18
Cooling System Safety
20
Others
21
2 Product Description
22
Model Description
22
Indoor Unit Components
23
Controller
25
Appearance and Ports
25
Function and Features
27
Monitoring System
28
Application Environment
31
Technical Specifications
35
3 Installation Guide
37
Installation Preparations
37
Preparing Tools
37
Material Preparations
40
Optional) Refrigerant R410A
41
Optional) Refrigerant Oil
42
Optional) Oil Trap and Inverted Trap
42
Humidifier Water Inlet Pipe
43
Drainpipe
44
Pipe Support
45
Cable
46
Engineering Procurement) Water Softener
48
Deployment Principles
48
Precautions
49
Installation Layout Principles
50
Unpacking
52
Checking Nitrogen Pressure
53
Removing the Cabinet Sheet Metal Fasteners
54
Installing the Cabinet Transport Tool
55
Removing the Transport Fasteners
58
Installation Flowchart
61
Installing the Indoor Unit
61
Preparing Knock-Out Holes
61
Leveling Feet
63
Optional) Installing the Enclosure Frame
63
Combining Cabinets
64
Securing the Indoor Unit
65
Installing Anchor Baffle Plates
68
Exhausting Nitrogen
69
Connecting Pipes
70
Connecting Refrigerant Pipes
70
Connecting Drainpipes
74
Optional) Connecting the Humidifier Water Inlet Pipe
77
Optional) Connect the Water Inlet Pipe to the Electrode Humidifier
77
Optional) Connect the Water Inlet Pipe to the Wet Film Humidifier
79
Leakage Test with Nitrogen
81
Connecting Cables
83
Port for Connecting the Power Cable
83
Connecting the Indoor Unit Power Cable
84
Connecting the Outdoor Unit Power Cable
88
Connecting Signal Cables
89
Preparations before Cable Connections
89
Connecting the Outdoor Unit On/Off Signal Cable
92
Connecting the Water Sensor Cable
93
Teamwork Networking and Monitoring
93
Main Control Module
94
Teamwork Network
95
CAN Teamwork Networking
95
FE Teamwork Networking
98
Monitoring and Organizing Network
99
Northbound RS485 Monitoring
99
FE Monitoring Network
101
Connecting T/H Sensors Outside Cabinets
102
Verification after Installation
105
4 Power-On Commissioning
108
Vacuumization and Refrigerant Precharging
108
Amount Requirements for the Refrigerant and Refrigerant Oil to be Charged
108
Vacuumizing
111
Precharging Refrigerant
113
Preparing for Power-On
116
Viewing Software Version Information
117
Power-On Commissioning (Software Version V200R001)
117
Powering on the Equipment
118
Home Screen
118
Initial Configuration
120
Setting Temperature and Humidity Values
120
Setting Teamwork Control Parameters
122
Setting Communications Parameters
130
Setting Communications Parameters (Modbus RTU Protocol)
130
Commissioning Procedure
131
Power-On Commissioning (Software Version V200R002)
134
Power-On
135
Home Screen
143
Initial Configuration
146
Setting Temperature and Humidity Values and Enabling T/H Sensors
146
Setting Teamwork Control Parameters
148
Setting Communications Parameters
156
Setting Communications Parameters (Modbus RTU Protocol)
156
Setting Communications Parameters (Modbus TCP Protocol)
156
Setting Communications Parameters (SNMP Protocol)
158
Optional) Setting WIFI Parameters
163
Startup
164
Charging the Remaining Refrigerant
168
Startup Wizard
171
Optional) Power-Off
179
5 Webui
180
Preparations and Webui Login
180
Webui Introduction
182
6 System Operation and Maintenance
185
Components
185
Routine Maintenance Overview
186
Maintenance Tools
187
Data Record
188
Monthly Maintenance
188
Semiannual Maintenance
191
Yearly Maintenance
191
Alarm Reference
192
Troubleshooting
232
Parts Replacement
237
Replacing the Air Filter
237
Replacing the Indoor Fan
238
Replacing the Differential Pressure Switch
239
Replacing the Compressor
241
Replacing the Welded Filter Dryer
244
Replacing the Threaded Filter Dryer
247
Replacing the Welded Filter Dryer with the Threaded Filter Dryer
250
Optional) Replacing a Wet Film Humidifier
254
Optional) Replacing the Humidifier Cylinder
258
Replacing the Electric Control Box
260
Replacing the T/H Sensor
262
Replacing the Module
263
Optional) Replacing the Liquid Level Detector
265
Optional) Replacing the Condenser Pump
268
Optional) Replacing a Humidifier Water Pump
271
Replacing the LCD
274
7 Faq
276
Operations on the LCD
276
Querying Temperature and Humidity Curves
276
Querying Logs
277
Querying Component Status
277
Querying System Parameters
278
Querying Version Details
279
How to View Teamwork Control Information
280
How to Silence the Buzzer
281
How Can I Handle Active Alarms
281
Deleting Historical Alarms
283
Deleting Logs
284
Clearing the Runtime
284
Calibrating a Sensor
284
Calibrating the Screen
285
How to Modify a Password
287
How to Set Alarm Parameters
288
How to Commission Single Component
290
Which Parameters Are Restored to Default Values after Default Settings Are Operated
291
Exporting Data
292
How to Export and Import a Configuration File
293
How to Import a Certificate and a Key
296
Webui Operations
297
How to Manage Webui Users
297
How to Install a Network Security Certificate
299
How Can I View Active Alarms and Historical Alarms
300
How Can I Export or Import a Configuration File
300
How Can I Export Fault Information
301
How Can I Change the Smart Cooling Product IP Address on the Webui
301
How Can I View Version Information
302
A Electric Control Box Layout
303
B Layout of the Cooling System
306
C Base Dimensions
308
D Indoor Unit Electrical Conceptual Diagram
310
E Acronyms and Abbreviations
316
Advertisement
Huawei NetCol5000-A025 User Manual (244 pages)
In-row Air Cooled Smart Cooling Product
Brand:
Huawei
| Category:
Air Conditioner
| Size: 26.9 MB
Table of Contents
About this Document
3
Table of Contents
7
1 Safety Information
11
General Safety
11
Personnel Requirements
14
Electrical Safety
14
Installation Environment Requirements
16
Mechanical Safety
18
Cooling System Safety
20
Others
21
2 Product Description
22
Model Description
22
Composition
23
Indoor Unit
23
Outdoor Unit
25
Controller
25
Monitoring System
27
Working Conditions
27
Technical Specifications
31
3 Installation Guide
34
Installation Preparation
34
Tools
34
Material Preparations
38
Optional) Refrigerant R410A
38
Refrigerant Oil
40
Pipe Components
40
Humidifier Water Inlet Pipe, Pump Drainpipe, and Automatic Drainpipe
41
Pipe Support
43
Cables
43
Deployment Principles
45
Unpacking
46
Checking the Air Pressure
47
Removing the Transport Fixing Sheet Metals
49
Removing the Transport Fasteners from Floats
49
Removing the Transport Fasteners from the Compressor
51
Install Process
52
Installing Indoor Units
53
Installing an Indoor Unit in Securing Mode
54
Installing an Indoor Unit in Non-Securing Mode
59
Installing an Outdoor Unit
60
Exhausting Nitrogen
60
Connecting Pipelines
61
Connecting Refrigerant Pipes
62
Connecting Water Pipes
66
Leak Checking
70
Installing Cabinet Accessories
73
Optional) Installing an Enclosure Frame
73
Optional) Installing the Top Frame
75
Connecting Cables
78
Preparations and Precautions
78
Connecting the Power Cable to an Indoor Unit
78
Installing the Voltage Jumper
79
Connecting the Signal Cables
79
Connecting the Outdoor Unit On/Off Signal Cable
82
Connecting Water Sensor
83
Teamwork Networking and Monitoring
84
Installing a Humidity and Temperature Sensor Outside the Cabinet
88
Connecting Monitoring Cable from FE Port
92
Connections Verification
92
4 ACC Introduction
95
Appearance
95
Controller Ports
96
Home Screen
96
Menu Hierarchy
98
Power-On Commissioning
99
Quick Settings
99
Initial Configuration
100
User Right Authentication
100
Start and Shutdown
101
Setting Temperature and Humidity Values
102
Setting Communications Parameters (IP Address Settings)
105
Setting Communications Parameters (Modbus Settings)
105
Setting Teamwork Control Parameters
107
Optional) Setting Alarm Parameters
115
Commissioning Guide
117
Entering Diagnostic Mode
117
Commissioning Smart Cooling Product Components
117
Maintenance Guide
118
Querying Parameters
119
Querying Temperature and Humidity Curves
119
Querying Alarms
120
Querying Logs
122
Querying Device Runtime
122
Querying Component Status
123
Querying System Parameters
124
Querying Version Details
125
Changing Parameters
125
Deleting Historical Alarms
125
Deleting Logs
126
Exporting Data
127
Clearing the Runtime
129
Calibrating a Sensor
129
Calibrating the Screen
130
Faq
132
How to Perform Quick Settings
132
How to Set the Language, Date, or Time
132
How to Change a Password
133
Restoring Factory Settings
134
How to Troubleshoot the Fault When the System Is in Upgrade Mode
136
How to Fast Shut down an Smart Cooling Product
137
How to Manually Clear Alarms
137
How to Enable a Humidity and Temperature Sensor
138
How to Check Teamwork Control Information
138
Which Parameters Are Restored to Default Values after Default Settings Are Operated
139
How to Change the SSH Access Password
139
Rectifying Faults of the E-Label Identification Board
142
Importing a Certificate and Key
144
Powering off and Maintaining a Smart Cooling Product in Icooling Linkage Mode
145
5 Power-On Commissioning
146
Commissioning Tools
146
Vacuumizing and Charging in Refrigerant
146
Calculation about the Charged the Refrigerant and Refrigerant Oil
146
Optional) Charging in Refrigerant Oil
148
Vacuumizing
149
Partially Charging Refrigerant
152
Commissioning Preparations
153
Checking before Power-On
153
Circuit Breakers
153
Power-On
154
Initial Configuration
155
Commissioning Procedure
155
Checking after Commissioning
160
Power off
160
6 System Operation and Maintenance
161
Maintenance Components
161
Routine Maintenance
162
Routine Maintenance Overview
162
Maintenance Tools
163
Data Record
164
Monthly Maintenance
165
Quarterly Maintenance
167
Yearly Maintenance
169
Alarm Reference
170
Troubleshooting
208
Parts Replacement
214
Replacing Filters
214
Replacing a Indoor Fan
215
Replacing a Compressor
217
Replacing the High Pressure Switch
220
Replacing Compressor Drive
222
Replacing a Huawei Compressor Drive
222
Replacing a Danfoss Compressor Drive
226
Replacing Condensate Pump
228
Replacing Humidifier Cylinder
230
Replacing Electric Heater
232
A Electrical Ports of an Indoor Unit
234
B General Layout
236
C Acronyms and Abbreviations
238
D Electric Diagram
240
E Main Control Board Diagram
241
F Humidifier Control Diagram
242
G Controller Menu Structure
243
Huawei NetCol5000-A025 User Manual (223 pages)
In-row Air Cooled Smart Cooling Product, 600 mm
Brand:
Huawei
| Category:
Accessories
| Size: 15.02 MB
Table of Contents
About this Document
3
Table of Contents
6
1 Safety Precautions
10
General Safety
10
Electrical Safety
12
Mechanical Safety
13
Operating Safety
14
Others
15
2 Product Description
17
Model Description
17
Composition
18
Indoor Unit
18
Outdoor Unit
20
Controller
20
Appearance and Ports
20
Functions and Features
23
Monitoring System
23
Working Conditions
24
Technical Specifications
28
3 Installation Guide
30
Installation Preparation
30
Tools
30
Material Preparations
33
Optional) Refrigerant R410A
34
Refrigerant Oil
36
Pipe Components
36
Humidifier Water Inlet Pipe, Pump Drainpipe, and Automatic Drainpipe
37
Pipe Support
39
Cables
39
Deployment Principles
40
Unpacking
43
Checking the Air Pressure
43
Removing the Transport Fixing Sheet Metals
45
Removing the Transport Fasteners from Floats
45
Removing the Transport Fasteners from the Compressor
47
Install Process
48
Installing Indoor Units
50
Installing an Indoor Unit in Securing Mode
50
Installing an Indoor Unit in Non-Securing Mode
55
Installing an Outdoor Unit
56
Exhausting Nitrogen
56
Connecting Pipelines
57
Connecting Refrigerant Pipes
58
Connecting Water Pipes
62
Leak Checking
65
Installing Cabinet Accessories
68
Optional) Installing an Enclosure Frame
68
Optional) Installing the Top Frame
70
Connecting Cables
73
Preparations and Precautions
73
Connecting the Power Cable to an Indoor Unit
73
Installing the Voltage Jumper
74
Connecting the Signal Cables
74
Connecting the Outdoor Unit On/Off Signal Cable
77
Connecting Water Sensor
77
Teamwork Networking and Monitoring
79
Installing a Humidity and Temperature Sensor Outside the Cabinet
82
Connecting Monitoring Cable from FE Port
85
Connections Verification
86
4 ACC Introduction
89
Home Screen
89
Menu Hierarchy
90
Power-On Commissioning
92
Quick Settings
92
Initial Configuration
92
User Right Authentication
93
Start and Shutdown
94
Setting Temperature and Humidity Values
94
Setting Communications Parameters (IP Address Settings)
96
Setting Communications Parameters (Modbus Settings)
97
Setting SNMP Parameters
99
Setting Teamwork Control Parameters
104
Optional) Setting Alarm Parameters
111
Commissioning Guide
113
Advertisement
Huawei NetCol5000-A025 Quick Manual (29 pages)
In-row Air Cooled Smart Cooling Product
Brand:
Huawei
| Category:
Air Conditioner
| Size: 3.63 MB
Table of Contents
Checking the Nitrogen Pressure
4
Installing the Indoor Unit
4
Installing the Outdoor Unit
6
Connecting the Refrigerant Pipe
8
Connecting Water Pipes
10
Installing Cables
12
Post-Installation Check
20
System Power-On
23
Optional) Power-Off
27
Checking after Commissioning
28
Advertisement
Related Products
Huawei NetCol5000-A-035
Huawei NetCol5000-A021HN12D 20020E1
Huawei NetCol5000-A021
Huawei NetCol5000-A021HN12D 2E120E1
Huawei NetCol5000-C030 Series
Huawei NetCol5000-C030H6B2010020E1
Huawei NetCol5000-C030H6B2010020E0
Huawei NetCol5000-C030H7B201E120E0
Huawei NetCol5000-C030H7B2010020E1
Huawei NetCol5000-C030H7A201E120E0
Huawei Categories
Cell Phone
Network Router
Wireless Router
Modem
Network Hardware
More Huawei Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL