4 Commissioning the MBTS in GU Mode on the M2000
Parameter Field
NodeB BaseLine
Software Version
NodeB Cold Patch
Version
NodeB Hot Patch
Version
NodeB
Configuration File
CRC
NodeB FTP Server
IP address
NodeB FTP Path
NodeB FTP User
Name
NodeB FTP
Password
BSC ID
BSC Name
GBTS ID
4-30
Description
The baseline version of the target NodeB (If the target version is
configured, the value is mandatory to be exported).
The value of this parameter is optional to be exported, and the
parameter cannot be edited in the MBTS Auto Deployment window.
The cold patch version of the target NodeB (If the target version is
configured, the value is mandatory to be exported).
The value of this parameter is optional to be exported, and the
parameter cannot be edited in the MBTS Auto Deployment window.
The hot patch version of the target NodeB (If the target version is
configured, the value is mandatory to be exported).
The value of this parameter is optional to be exported, and the
parameter cannot be edited in the MBTS Auto Deployment window.
The CRC value of the NodeB data configuration file.
The value of this parameter is optional to be exported, and the
parameter cannot be edited in the MBTS Auto Deployment window.
FTP server IP address of the NodeB.
The value of this parameter is optional to be exported, and the
parameter cannot be edited in the MBTS Auto Deployment window.
The FTP path of the NodeB.
The value of this parameter is optional to be exported, and the
parameter cannot be edited in the MBTS Auto Deployment window.
The FTP user of the NodeB.
The value of this parameter is optional to be exported, and the
parameter cannot be edited in the MBTS Auto Deployment window.
The FTP password of the NodeB.
The value of this parameter is optional to be exported, and the
parameter cannot be edited in the MBTS Auto Deployment window.
The ID of the BSC to which the GBTS belongs (If the parameter is
configured, the value is mandatory to be exported).
The value of this parameter is optional to be exported, and the
parameter cannot be edited in the MBTS Auto Deployment window.
The name of the BSC to which the GBTS belongs.
The value of this parameter is optional to be exported, and the
parameter cannot be edited in the MBTS Auto Deployment window.
GBTS ID.
The value of this parameter is mandatory to be exported, and the
parameter cannot be edited in the MBTS Auto Deployment window.
Huawei Proprietary and Confidential