Xor - ABB ACSM1 Manual

Motion control system
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

XOR

(10017)
Illustration
Execution time
Operation
Inputs
Outputs
1.24 µs (when two inputs are used) + 0.72 µs (for every additional input). When all
inputs are used, the execution time is 22.85 µs.
The output (OUT) is 1 if one of the connected inputs (IN1...IN32) is 1. Output is zero if
all the inputs have the same value.
Example:
IN1
IN2
OUT
0
0
0
0
1
1
1
0
1
1
1
0
The inputs can be inverted.
The number of inputs (2...32) is selected by the user.
Input (IN1...IN32): Boolean
Output (OUT): Boolean