52 Fba Data In; Group 52 Fba Data In - ABB ACSM1 Manual

Motion control system
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

Group

52 FBA DATA IN

These parameters select the data to be sent by the drive to the fieldbus controller,
and need to be set only if a fieldbus adapter module is installed. See also
A – Fieldbus control
Notes:
• This parameter group is presented in the User's Manual of the fieldbus adapter as
parameter group 3 or C.
• The new settings will take effect when the drive is powered up the next time
(before powering off the drive, wait at least 1 minute), or when parameter
FBA PAR REFRESH
• The maximum number of data words is protocol-dependent.
52
52.01 FBA DATA IN1
Selects data to be transferred from the drive to the fieldbus controller.
0
4
5
6
14
15
16
101...9999
52.02 FBA DATA IN2
...
...
52.12 FBA DATA IN12
See
on page 423.
is activated.
52.01 FBA DATA
IN1.
FW block: None
Not in use.
Status Word (16 bits).
Actual value 1 (16 bits).
Actual value 2 (16 bits).
Status Word (32 bits).
Actual value 1 (32 bits).
Actual value 2 (32 bits).
Parameter index.
FW block: None
FW block: None
Appendix
Parameters and firmware blocks
211
51.27