ABB ACSM1 Manual page 131

Motion control system
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

12.10 DIO3 F MAX SCALE
When
12.03 DIO3 CONF
parameter
12.07 DIO3 F OUT
(defined by parameter
f
(Hz)
DIO3
12.08
12.09
12.11
0...32768
12.11 DIO3 F MIN SCALE
When
12.03 DIO3 CONF
parameter
12.07 DIO3 F OUT
(defined by parameter
0...32768
Firmware block:
RO
(5)
Connects an actual signal to the relay
output. The block also shows the
relay output status.
Block outputs located in other
parameter groups
12.12 RO1 OUT PTR
Selects a drive signal to be connected to relay output RO1.
Bit pointer: Group, index and bit
Firmware block:
DI
(4)
Shows the status of the digital inputs.
Inverts the status of any DI if desired.
Block outputs located in other
parameter groups
FW block:
DIO3
is set to
(2) Freq
output, defines the real value of the signal (selected by
PTR) that corresponds to the maximum DIO3 frequency output value
12.08 DIO3 F
MAX).
12.10
Signal (real)
selected by
par.
12.07
Real signal value corresponding to maximum DIO3 output frequency.
FW block:
DIO3
is set to
(2) Freq
output, defines the real value of the signal (selected by
PTR) that corresponds to the minimum DIO3 frequency output value
12.09 DIO3 F
MIN).
Real signal value corresponding to minimum DIO3 output frequency.
2.02 RO STATUS
FW block:
RO
(see above)
2.01 DI STATUS
(see above)
f
(Hz)
DIO3
12.08
12.09
12.10
12.11
(see above)
RO
(page 94)
DI
(page 94)
Parameters and firmware blocks
131
Signal (real)
selected by
par.
12.07

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents