Group 68 Sync Ref Mod - ABB ACSM1 Manual

Motion control system
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

Group
68 SYNC REF MOD
Synchronisation reference modification settings that are used to select between
absolute or relative synchronisation, to set an electrical gear ratio between the
synchronisation reference and the drive positioning system, and to filter the
reference.
68.05 SYNC REF FTIME
68.04 SYNC GEAR ADD
68.02 SYNC GEAR MUL
68.01 SYNC GEAR IN
68.03 SYNC GEAR DIV
68.07 SYNCHRON MODE
68.06 SYNCFILT DLY LIM
68
Firmware block:
SYNC REF MOD
(68)
This block
• selects the source for the synchron
reference chain
• defines the gear ratio and selects a
scaling factor for the ratio (in
synchron control the position
reference is first multiplied with the
defined gear ratio and then with the
defined gear scaling factor)
• defines the synchron speed
reference filter time
• defines the maximum position
difference between the unfiltered
and filtered synchron speed
reference
• selects the synchronisation of the
follower drive in synchron control
mode
• shows the position reference in
synchron control mode.
Block outputs located in other
parameter groups
68.01 SYNC GEAR IN
Selects the source for the synchron reference chain. The default value is P.4.15, ie, parameter
SYNC REF
Value pointer: Group and index
x
d
y
dt
4.16 SYNC REF GEARED
FW block:
UNGEAR, which is the output of the
x
dt
SYNC REF MOD
(page 104)
SYNC REF MOD
(see above)
SYNC REF SEL
firmware block (on page 244).
Parameters and firmware blocks
4.16 SYNC REF GEARED
4.15
247

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents