Table 4-18. Timing2 Register; Table 4-19. Timing2 Fields; Clock And Signal Polarity Control Register (Timing2) - Sharp LH79524 User Manual

Table of Contents

Advertisement

Color Liquid Crystal Display Controller

4.5.3.3 Clock and Signal Polarity Control Register (TIMING2)

The TIMING2 Register controls the CLCDC timing.
BIT
FIELD
RESET
RW
BIT
FIELD
RESET
RW
ADDR
BIT
31:27 PCD_HI
26
25:16
15
14
13
12
4-24

Table 4-18. TIMING2 Register

31
30
29
28
27
PCD_HI
0
0
0
0
RW
RW
RW
RW
RW
15
14
13
12
11
///
IOE
IPC
IHS
IVS
0
0
0
0
RO
RW
RW
RW
RW
NAME
Panel Clock Divisor (upper five bits) The ten-bit PCD field, comprising PCD_HI
and PCD_LO (bits [4:0]) is used to derive the LCD Panel clock frequency CLCP from the
CLCDCLK frequency: CLCP = CLCDCLK/(PCD + 2).
For mono STN displays with a four or eight-bit interface, the panel clock is a factor of four
and eight of the actual individual pixel clock rate. For color STN displays, 2 2/3 pixels are
output per CLCP cycle, therefore the panel clock is 0.375 times.
For TFT displays the pixel clock divider can be bypassed by setting the TIMING2:BCD bit.
Bypass Pixel Clock Divider
1 = Bypass the pixel clock divider logic
BCD
0 = Use the pixel clock divider logic
See the description of the PCD bit field, below.
Clocks Per Line CPL specifies the number of LCDDCLK pulses fed to the LCD panel
during each horizontal line. The TIMING2:CPL and TIMING0:PPL fields work together;
both must be programmed correctly in order for the CLCDC to function correctly.
Actual Pixels Per Line (APPL) = 16 x (TIMING0:PPL – 1)
CPL
TFT panels: CPL = (APPL – 1)
4-bit mono STN panels: CPL = ((APPL/4) – 1)
8-bit mono STN panels: CPL = ((APPL/8) – 1)
Color STN panels: CPL = (((3 x APPL) / 8) – 1)
///
Reserved Reading returns 0. Write the reset value.
Invert Output Enable IOE applies only to TFT modes and should be programmed
to 0 for all other modes. In the TFT mode, the LCDEN pin indicates to the LCD panel that
valid display data is available. IOE selects the active polarity of this output enable signal.
In the TFT mode, data is driven onto the LCD data lines at the programmed edge of LCD-
IOE
DCLK when LCDEN is asserted.
1 = The LCDEN output pin is active LOW
0 = The LCDEN output pin is active HIGH
Invert Panel Clock IPC selects the active edge of the LCDDCLK signal.
IPC
1 = Data is driven on the LCD data lines on the falling-edge of LCDDCLK
0 = Data is driven on the LCD data lines on the rising-edge of LCDDCLK
Invert Horizontal Synchronization IHS selects the polarity of the LCDLP signal.
IHS
1 = The LCDLP pin is active LOW
0 = The LCDLP pin is active HIGH
26
25
24
23
BCD
0
0
0
0
0
RW
RW
RW
RW
10
9
8
7
ACB
0
0
0
0
0
RW
RW
RW
RW
0xFFFF4000 + 0x08

Table 4-19. TIMING2 Fields

DESCRIPTION
Version 1.0
LH79524/LH79525 User's Guide
22
21
20
19
18
CPL
0
0
0
0
0
RW
RW
RW
RW
RW
6
5
4
3
2
///
PCD_LO
0
0
0
0
0
RW
RO
RW
RW
RW
17
16
0
0
RW
RW
1
0
0
0
RW
RW