SUB-MATRIX
DIGITAL
DEFINITION:
HOW TO MODIFY IT:
POSSIBLE CHOICES:
SEE ALSO:
WARNING:
PARAMETER
ACTION
Action on printer in case of digital input change.
Select a new action.
NO ACTION: No effect on printing.
CHG SPD/INT: Change chart speed/print interval.
CHG RANGE: Change to range 2 if RANGE USED = with R1 and to range 1
if RANGE USED = with R2
PRINT ON AL: Print the channel in alarm condition.
PRT INHIBIT: Stop all printing without data memorization.
TAB SQTRACE: Print one tabular snapshot of values superposed on traces.
TAB SQBLANK: Print one tabular snapshot of values on blank paper.
PRT MATH LOG: Print one tabular snapshot of maths results.
CHG GROUP B:
CHG GROUP A to B: Print groups # i of channels defined in chart sub-matrix
When the alarm turns ON, the group B is printed.
When the alarm turns OFF, the group A is printed.
CHG GROUP AB:
CHG GROUP A to A + B: Print groups # i of channels defined in chart
sub-matrix.
When the alarm turns ON, groups A and B are printed.
When the alarm turns OFF, the group A is printed.
RANGE USED in CHART sub-matrix for PRINT ON AL and CHG GROUP
GROUP DEF in CHART sub-matrix for CHG GROUP
This ACTION parameter is taken into account only if NORMAL is selected for
the SELECTION parameter of the DIGITAL sub-matrix.
4. CONFIGURATION
4-51