Huawei OceanStor N8500 T Series Installation Manual page 232

Clustered nas storage system
Table of Contents

Advertisement

OceanStor N8500 Clustered NAS Storage System
Installation Guide (for T Series V100R005)
No.
5
6
7
8
9
10
11
12
Issue 02 (2015-09-22)
Indicator Name
Link indicator of the
management
network port
Link indicator of the
expansion port
Indicator of the 10
Gbit/s TOE host port
Link/Speed indicator
of the Fibre Channel
port
Power indicator of
the controller
Alarm indicator of
the controller
Power indicator of
the enclosure
Alarm indicator of
the enclosure
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 N8500 Installation (with S5600T, S5800T or S6800T
Storage System as the Storage Unit)
Status and Description
l Green and on: The link to the management network
port is up.
l Off: The link to the management network port is
down.
l Blue and on: Data is transferred to the SUD at a rate
of 4 x 6 Gbit/s.
l Green and on: Data is transferred to the SUD at a rate
of 4 x 3 Gbit/s.
l Red and on: The port is faulty.
l Off: The link to the port is down.
l Blue and on: The data transfer rate between the
storage system and the application server is 10 Gbit/
s.
l Blue and blinking: Data transfer is in progress.
l Red and on: The port is faulty.
l Off: The link of the port is down.
l Blue and on: Data is transferred at a rate of 8 Gbit/s.
l Blue and blinking: Data is being transferred.
l Green and on: Data is transferred at a rate of 4 Gbit/
s or 2 Gbit/s.
l Green and blinking: Data is being transferred.
l Red and on: The port is faulty.
l Red and blinking: The port is being located.
l Off: The link to the port is down.
l Green on: The controller is properly powered on.
l Green and blinking: The system is being started.
l Off: The controller is not powered on.
l Steady red: An alarm is generated on the controller.
l Off: The controller is working properly.
l Green and on: The controller enclosure is powered
on.
l Green and blinking: The controller enclosure is being
powered on or powered off.
l Off: The controller enclosure is not powered on.
l Steady red: The controller enclosure is out of service,
or an alarm is generated on it.
l Off: The controller enclosure is working properly.
223