MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Data object
CDC
name
TagOn
SPS
TagOff
SPS
TapLocFlt
SPS
TdrTrbl
SPS
TempMnt
SPS
TestMod
SPS
3
TestPrgInd
SPS
ThmCap
MV
ThmLOTm
MV
ThrdEthFail
SPS
TmChgOp1
SPS
TmnsDelta
MV
TmOfClc
INS
TmOfMax
INS
TmStr1
SPS
ToOilTmp
MV
TotLOTm
MV
Tr1p
ACT
Tr3p
ACT
Tr3pFrcd
SPS
TransBlk
SPS
TrcHz
MV
Trigger11
ENS
Trigger21
ENS
TripInd
SPS
3-222
Semantics
Breaker tagged.
The BREAKER 1 TAG ON operand.
Breaker not tagged.
The BREAKER 1 TAG OFF operand.
L90 - The fault is identified between the local terminal and the tap point.
The TAP-LOCAL FAULT operand.
TDR trouble.
The TDR TROUBLE operand.
The ambient temperature is greater than the maximum operating temperature.
The TEMP MONITOR operand.
LED indication - Relay in Test Mode.
The LED TEST MODE operand.
LED indication - Test In-Progress.
The LED TEST IN PROGRESS operand.
% thermal model motor unbalance.
MOTOR THERMAL CAPACITY USED in percentage (%).
Indicates Thermal Lockout for the motor.
THERMAL LOCKOUT TIME in seconds.
Third Ethernet failure.
The THIRD ETHERNET FAIL operand.
Change in round trip delay on the channel exceeded pre-set value.
87L DIFF CH 1 TIME CHNG operand, which becomes On when the Change in round
trip delay on channel 1 exceeded preset value.
PTP-IRIG-B Delta in ns
Represents the UTC time of the broken rotor bar calculation in seconds elapsed
since 1970/01/01, 00.00.00.
The TIME OF BRB CALC. actual value.
The TIME OF MAXIMUM BRB actual value
Power swing timer picked up.
The POWER SWING TMR2 PKP operand.
Indicates top oil temperature.
The TOP OIL degrees C actual value.
Indicates total lockout time for the motor. TOTAL MOTOR LOCKOUT TIME in
seconds.
Single pole trip operation initiated.
The 87L TRIP 1P OP operand.
General is TRIP 1-POLE operand, phsA is TRIP PHASE A operand, phsB is TRIP
PHASE B operand, and phsC is TRIP PHASE C operand.
Three pole trip operation initiated.
The DCUB TRIP 3P operand.
The DIR BLOCK1 TRIP 3P operand.
The DUTT TRIP 3P operand.
The HYBRID POTT TRIP 3P operand.
The 87L TRIP 3P OP operand.
The POTT1 TRIP 3P operand.
The PUTT TRIP 3P operand.
The TRIP 3-POLE operand.
Three pole trip mode is being forced.
The TRIP FORCE 3-POLE operand (3-pole trip mode is being forced).
Phase comparison transient blocking has operated.
The 87PC TRANS BLOCK OP operand.
B90 frequency
Represents the Hi-Z Data Capture 1 trigger type
Represents the Hi-Z Data Capture 1 RMS type
LED indication - Element Trip Indication.
The LED TRIP operand.
CHAPTER 3: IEC 61850 COMMUNICATION
Used in logical nodes...
Bkr0XCBR
Bkr0XCBR
FltRptRFLO
LPHD
LPHD
LEDsIHMI
LEDsIHMI
MotThmPTTR
MotThmPTTR
LPHD
LinDfPDIF
TmClkLTMS
BknRotSVBR
BknRotSVBR
PwrSwgRPSB
HPTmpSPTR
MotThmPTTR
LinDfPDIF, TrOutPTRC
DCB_PSCH, DCB1_PSCH,
DCUB_PSCH, DUTT_PSCH,
HPOTT_PSCH, LinDfPDIF,
POTT_PSCH, POTT1_PSCH,
PUTT_PSCH, TrOutPTRC
TrOutPTRC
PhCmp1PDIF
B_FrqMMXN
HiZPHIZ
HiZPHIZ
LEDsIHMI