GE B30 Communications Manual page 448

Universal relay family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Data object
CDC
name
Activated
SPS
Adif
CMV
Agnd
CMV
AgndRMS
MV
3
AlgCap
SPC
AlmInd
SPS
AmpInd
SPS
AnFailBeh
ENG
AnFailVal
ASG
AnOutput1
MV
AnyPBOn
SPS
AnyErr
SPS
AnyGpsFail
SPS
AnyPoleOpn
SPS
AnyShotCnt
SPS
APPID
ING
ArBlk1
SPS
ArcConfid1
INS
ArcSuspect
ACT
AresRMS
MV
ArLO
SPS
Armed
SPS
ArMod1
SPS
ArRip
SPS
ASupn1
SPS
Asymmetry
SPS
AutoMod
SPS
3-210
Semantics
Activated. In this logical node, indicates position of a pushbutton. When "true", the
pushbutton is asserted state; when "false", the pushbutton is in a released state.
CONTROL PUSH BUTTON 1 ON operand.
PUSHBUTTON 1 ON operand.
Differential current (sum of the three phase currents and the ground (fourth)
current. Restricted ground differential if the fourth current measures the ground
current in a grounded wye winding. Measures CT secondary circuit trouble if
fourth current measures the CT secondary neutral current.
SRC 1 Differential Ground Current phasor, in primary volts.
Ground current (fourth input in a current AC bank).
SRC 1 Ground Current phasor, in primary amperes.
Ground current RMS (fourth input in a current AC bank).
SRC 1 Ground Current RMS, in primary amperes.
Command for the Hi-Z Oscillography Force Algorithm Capture
An LED.
The LED ALARM operand.
An LED.
The LED CURRENT operand.
Setting to select the behavior of the RxGOOSE Analog when the sending device is
offline: 0 = Default Value, 1 = Last Known
The value of the RxGOOSE Analog when the sending device is offline and the
FailBeh is set to "Default Value"
Analog output
Indicates ANY PB ON operand state. When any of the user pushbuttons is
asserted, status is "true"; when none of the user pushbuttons are asserted, status
is "false."
Any of the self-test errors generated. The ANY SELF TESTS operand.
The GPS signal failed or is not configured properly at any terminal.
The 87L DIFF GPS FAIL operand, which becomes On when the GPS signal failed or
is not configured properly at any terminal.
At least one pole is open. The BREAKER 1 ANY P OPEN operand.
The first breaker close signal has been issued.
The AR SHOT CNT greater than zero operand.
Expected value of APPID field in messages subscribed to by RxGOOSE#
The RxGOOSE1 ETYPE APPID setting.
Autoreclose Breaker number indicated by the data instance number is
temporarily disabled.
The AR BKR1 BLK operand and the AR1 BLK FROM MAN CLS operand.
Represents the Arc Confidence in percentage for Phase A, B, C, or N
Indicates suspected element has operated
Residual Current RMS.
SRC 1 Neutral Current RMS, in primary amperes.
Autoreclose is locked out. The AR LO operand.
Accidental energization. Occurs when the generator is offline with no fault
involved. The ACCDNT ENRG ARMED operand.
Autoreclosec mode equals to the number indicated by the data instance number,
in this case 1 and 3 pole mode. The AR MODE = 1 operand.
Autoreclose is in progress. The AR RIP operand.
Indicates the state of current supervision.
The PHS DIST Z1 SUPN AB/BC/CA operand in Phase-To-Phase.
Communications channel asymmetry detected.
The 87L DIFF CH ASYM DET operand, which becomes On when the differential
element's has detected substantial communications channel asymmetry.
Capacitor control in auto mode. The CAP 1 IN AUTO operand.
CHAPTER 3: IEC 61850 COMMUNICATION
Used in logical nodes...
CtlPshIHMI, UsrPbIHMI
ACsrcMMXU
ACsrcMMXN
ACsrcMMXN
HiZPHIZ
LEDsIHMI
LEDsIHMI
GGIO3
GGIO3
Cmp8BtGAPC
UsrPbIHMI
LPHD
LinDfPDIF
Bkr0XCBR
Rec13pRREC
LGOS
Rec13pRREC, Rec3pRREC
HiZPHIZ
HiZPHIZ
ACsrcMMXU
Rec13pRREC, Rec3pRREC
AcdEnrPIOC
Rec13pRREC
Rec13pRREC, Rec3pRREC
PhsDisPDIS
LinDfPDIF
CapCtlGAPC
UR FAMILY – COMMUNICATIONS GUIDE