MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Data object
CDC
name
RlyUTCTms
INS
RrtdComFail
SPS
Rs
SPS
RsOp
SPS
RsOpLoc
SPS
RsOpPB
SPS
3
RsOpRem
SPS
RsTms
INS
RtdTrbl
SPS
Running
SPS
RvOp
SPS
RX1
SPS
RxGooseOff
SPS
Sat1
SPS
Sat1
SPS
SbstCls
SPS
SbstOpn
SPS
SecDataClr
SPC
SecEna
ENG
SecEthFail
SPS
SecondOfDay
INS
SeqTO
SPS
SHAmpAng
MV
ShotCnt1
SPS
ShrtCirc
SPS
Sim
SPC
3-220
Semantics
Represents the relay UTC time in seconds elapsed since 00:00:00 January 1, 1970.
Mapped to Modbus register 41A0h value, that is, "Relay time clock set time"
register value after converting to UTC (if time zone and DST is used).
RRTD communication failure.
The RRTD COMM FAIL operand.
Autoreclose has been reset either manually or by the rest timer.
The AR RESET operand.
Target resetting - General indication (binary input).
The RESET OP operand value.
Target resetting - General indication (binary input).
The RESET OP (OPERAND) operand value.
Target resetting - General indication (binary input).
The RESET OP (PUSHBUTTON) operand value.
Target resetting - General indication (binary input).
The RESET OP (COMMS) operand value.
The UTC time of the last clear in seconds elapsed since 00:00:00 January 1, 1970.
The LAST CLEARED DATE actual value.
RTD trouble.
The RTD TROUBLE operand.
Indicate the motor is running.
The MOTOR RUNNING operand.
Fault direction is reverse.
The NEG SEQ DIR OC1 REV operand.
The NTRL DIR OC1 REV operand.
Pulse received on channel 1 or 2.
The 87PC RX1 operand.
One or more RxGOOSE is not responding.
The RxGOOSE OFF operand.
Indicates CT saturation is detected.
The BUS 1 SAT A/B/C operand.
Indicates phase saturation of differential is detected per phase
The STATOR DIFF1 SAT A/B/C operand.
Manually substituted to close.
The BREAKER 1 SUBD CLSD operand.
Manually substituted to open.
The BREAKER 1 SUBD OPEN operand.
Command CLEAR SECURITY DATA, TRUE = CLEAR SECURITY DATA
RxRGOOSE1 Security Ena setting: 0=None; 1=Signature; 2=Signature and
Encryption. Otherwise ignored.
Second Ethernet failure.
The SECOND ETHERNET FAIL operand.
Represents integer number of seconds past midnight (Range1-86400).
The SecondOfDay actual value in seconds.
The incomplete sequence timer timed out.
The AR INCOMPLETE SEQ operand.
Sub harmonic current angle.
SH CURRENT ANGLE in degrees.
Autoreclosec shot count is equal to the number indicated by the data instance
number.
The AR SHOT CNT=1 operand.
Short circuit detected.
The RRTD RTD 1 SHORTED operand.
The RTD Ip 1 SHORTED operand.
Simulated GOOSE values or simulated sampled measurand values are used
instead of original values since they are first received
CHAPTER 3: IEC 61850 COMMUNICATION
Used in logical nodes...
LPHD
LPHD
Rec13pRREC
TgtRsIHMI
TgtRsIHMI
TgtRsIHMI
TgtRsIHMI
OscRDRE
LPHD
MotThmPTTR
NegDocRDIR, NeuDocRDIR
PhCmp1PDIF
LPHD
B_DifPDIF, BusDifPDIF
SttDifPDIF
Bkr0XCBR
Bkr0XCBR
SecGSAL
LGOS
LPHD
TmDayGAPC
Rec13pRREC
SubHaPHIZ
Rec13pRREC, Rec3pRREC
PRTDsSTMP, RRTDsSTMP
LPHD