GE B30 Communications Manual page 306

Universal relay family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
LNName: LinDf2MMXU1
data obj. data attribute
phsθ.instCVal
phsθ.instCVal.mag
.f
phsθ.instCVal.ang
.f
phsθ.cVal
phsθ.cVal.mag.f
phsθ.cVal.ang.f
phsθ.units
phsθ.units.SIUnit ENUMERATED
phsθ.units
.multiplier
3
phsθ.db
phsθ.dbAng
phsθ.zeroDb
angRef
3.5.2.32 Line pickup (LinPkp)
This element is instantiated in the following products: D30, D60, L60, L90.
Table 3-59: Line pickup data objects
LNName: LinPkpPIOC1
data obj. data attribute
Str
general
dirGeneral
Op
general
Dpo
stVal
UnAφ
stVal
UnV
stVal
LeoSt
stVal
Zn2Tr
stVal
BlkRefγ
setSrcRef
setSrcCB
3.5.2.33 Load encroachment (LodEn)
This element is instantiated in the following products: D30, D60, F60, L60, L90, T60.
3-68
LDevice inst: Prot
UR element: Line Differential element (ANSI 87L) – terminal 2 current
function
Type
FC UR Name
Vector
MX
FLOAT32
TERMINAL 2 Iθ magnitude, in
primary amps
FLOAT32
TERMINAL 2
Vector
MX
FLOAT32
TERMINAL 2 Iθ magnitude, in
primary amps, with deadband
FLOAT32
TERMINAL 2
Unit
CF
ENUMERATED
INT32U
CF
LinDf2MMXU1.A.phsθ.db
INT32U
CF
LinDf2MMXU1.A.phsθ.dbAng
INT32U
CF
CURRENT CUT-OFF LEVEL setting
multiplied by 100000/46.
ENUMERATED
CF
LDevice inst: Prot
UR element: Line Pickup functions
Type
FC UR Name
ACD
BOOLEAN
ST
LINE PICKUP PKP
ENUMERATED
ST
ACT
BOOLEAN
ST
LINE PICKUP OP
SPS
BOOLEAN
ST
LINE PICKUP DPO
SPS
BOOLEAN
ST
LINE PICKUP I<θ
SPS
BOOLEAN
ST
LINE PICKUP UV PKP
SPS
BOOLEAN
ST
LINE PICKUP LEO PKP
SPS
BOOLEAN
ST
LINE PICKUP RCL TRIP
ORG
ObjectReference SP
LINE PICKUP BLOCK for group γ. reference to the data attribute to input
ObjectReference SP
CHAPTER 3: IEC 61850 COMMUNICATION
Description
UR range -180...+180 converted to 0...360 R
UR range -180...+180 converted to 0...360 R
5, the code for amps
0, the code for a multiplier of 1
See UR product manual regarding
FREQUENCY AND PHASE REFERENCE
Description
LINE PICKUP PKP operand
0, the code for unknown. It is unknown as
the element is non-directional
LINE PICKUP OP operand
LINE PICKUP DPO operand, which is the
inverse of LINE PICKUP PKP
LINE PICKUP operand that activates on
phase θ current below 5% of nominal
LINE PICKUP UV PKP operand
LINE PICKUP LEO PKP operand
LINE PICKUP RCL TRIP operand
LINE PICKUP BLOCK setting for setting
group γ.
source GoCB of input if via GOOSE
UR FAMILY – COMMUNICATIONS GUIDE
R/W/C
R
R
R
R
R
R
R
R/W/C
R/W/C
R
R
R/W/C
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R/C
R/C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents