MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Data object
CDC
name
NeutSupn
SPS
NeutVx
CMV
NumCycPer
INS
Off
SPS
Offline
SPS
On
SPS
OnePoleOpn
SPS
3
OnePU
ASG
OpAlm
ACT
OpBia
ACT
OpHiSet
ACT
OpLoSet
ACT
OpnCirc
SPS
OpnSt1
SPS
OpPhs1
SPS
OpSig
MV
OpUnBia
ACT
OpV
WYE
OscilGOOSE
SPS
OtherInd
SPS
OvlTripTm
MV
OutOfSrv
SPS
P1Rip
SPS
P3Rip1
SPS
P3Tr
SPS
PFLLfail
SPS
3-218
Semantics
Neutral overcurrent supervision status.
The GND DIST Z1 SUPN IN operand.
Neutral point voltage in pu
Number of cycles of the nominal frequency. The CYCLES PER RECORD actual
value.
Logic 0 fixed operand
Indicate the motor is offline.
The MOTOR OFFLINE operand.
Logic 1 fixed operand
One pole is open, others closed.
The BREAKER 1 ONE P OPEN operand.
The per-unit base factor applied to the corresponding RxGOOSE analog input
FlexAnalog quantity to normalize it to a per-unit quantity.
Operate indicates the alarm decision of a protection function.
The U/CURR ALARM OP operand.
The UNDERPWR 1 ALARM OP operand.
B90 Operate indicates the trip decision of a biased protection logic
B90 Operate indicates the trip decision of the HISET element of breaker failure
current supervision function.
B90 Operate indicates the trip decision of the LOSET element of breaker failure
current supervision function.
Open circuit detected.
The RRTD RTD 1 OPEN operand.
The RTD Ip 1 OPEN operand.
Open status detected.
The BREAKER/SWITCH OPEN operand.
The RxGOOSE DPS1 Off operand.
Indicates a trip decision for a particular cause per phase.
The BUS 1 BIASED OP A/B/C operand.
The BUS 1 UNBIASED OP A/B/C operand.
The PHS DIST Z1 OP AB/BC/CA operand.
Operating signal, the analogue value used by the comparator.
FLEXELEMENT 1 OpSig, in per unit.
B90 Operate indicates the trip decision of an unbiased protection logic
Phase Operating Voltages.
Bank Operating Voltage in per unit for Phase A, B, and C.
One or more of GGIO1.Ind###.stVal has been frozen due to frequent status
changes (chatter) in the mapped operand.
The Oscillatory GOOSE operand.
An LED.
The LED OTHER operand.
Indicates estimation of trip time on overload.
The ESTIMATED TRIP TIME ON OVERLOAD in seconds.
Out-of-service.
The BREAKER 1 OOS operand.
Autoreclose A single pole is in progress.
The AR 1-P RIP operand.
Autoreclose 3-pole is in progress via dead time number indicated by the data
instance number.
The AR 3-P/1 RIP operand.
Force any trip to 3-phase trip.
The AR FORCE 3-P TRIP operand.
Phase and/or frequency lock loop (PFLL) has failed.
The 87L DIFF PFLL FAIL operand, which becomes On when the differential
element's phase and frequency lock loop (PFLL) has failed.
CHAPTER 3: IEC 61850 COMMUNICATION
Used in logical nodes...
GndDisPDIS
NuVUnPTOV
OscRDRE
Master/LLN0
MotThmPTTR
Master/LLN0
Bkr0XCBR
GGIO3
UnCurPTUC, UnPwrPDUP
B_DifPDIF
B_BFaiPIOC
B_BFaiPIOC
PRTDsSTMP, RRTDsSTMP
BkrΘXCBR, Bkr0XCBR,
Disc0XSWI, DiscΘXSWI,
GGIO3
BusDifPDIF, PhsDisPDIS
FlxElGAPC
B_DifPDIF
CPhOvPTOV
LPHD
LEDsIHMI
MotThmPTTR
Bkr0XCBR
Rec13pRREC
Rec13pRREC
Rec13pRREC
LinDfPDIF