MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
LNName: ACsrcMMXU#
data obj. data attribute
phsA.cVal.ang.f
phsA.units
phsA.units.SIUnit ENUMERATED
phsA.units
.multiplier
phsA.db
phsA.dbAng
phsA.zeroDb
phsB
phsB.instCVal
phsB.instCVal.mag
.f
3
phsB.instCVal.ang
.f
phsB.cVal
phsB.cVal.mag.f
phsB.cVal.ang.f
phsB.units
phsB.units.SIUnit ENUMERATED
phsB.units
.multiplier
phsB.db
phsB.dbAng
phsB.zeroDb
phsC
phsC.instCVal
phsC.instCVal.mag
.f
phsC.instCVal.ang
.f
phsC.cVal
phsC.cVal.mag.f
phsC.cVal.ang.f
phsC.units
phsC.units.SIUnit ENUMERATED
phsC.units
.multiplier
phsC.db
phsC.dbAng
phsC.zeroDb
res
res.instCVal
res.instCVal.mag
.f
res.instCVal.ang
.f
res.cVal
res.cVal.mag.f
res.cVal.ang.f
res.units
res.units.SIUnit
res.units
.multiplier
res.db
res.dbAng
3-178
LDevice inst: Meter
UR element: AC Source #
Type
FC UR Name
FLOAT32
Unit
CF
ENUMERATED
INT32U
CF
MMXU# A.phsA .db
INT32U
CF
MMXU# A.phsA.dbAng
INT32U
CF
CMV
Vector
MX
FLOAT32
SRC # Phase B Current
Magnitude
FLOAT32
SRC # Phase B Current Angle
Vector
MX
FLOAT32
FLOAT32
Unit
CF
ENUMERATED
INT32U
CF
MMXU# A.phsB.db
INT32U
CF
MMXU# A.phsB.dbAng
INT32U
CF
CMV
Vector
MX
FLOAT32
SRC # Phase C Current
Magnitude
FLOAT32
SRC # Phase C Current Angle
Vector
MX
FLOAT32
FLOAT32
Unit
CF
ENUMERATED
INT32U
CF
MMXU# A.phsC.db
INT32U
CF
MMXU# A.phsC.dbAng
INT32U
CF
CMV
Vector
MX
FLOAT32
SRC # Neutral Current
Magnitude
FLOAT32
SRC # Neutral Current Angle
Vector
MX
FLOAT32
FLOAT32
Unit
CF
ENUMERATED
ENUMERATED
INT32U
CF
MMXU# A.neut.db
INT32U
CF
MMXU# A.neut.dbAng
CHAPTER 3: IEC 61850 COMMUNICATION
Description
instCVal.ang.f deadbanded
5, the code for primary amperes
0, the code for a multiplier of 1
current cut-off level.
UR range -180...+180 converted to 0...360 R
instCVal.mag.f deadbanded
instCVal.ang.f deadbanded
5, the code for primary amperes
0, the code for a multiplier of 1
current cut-off level.
UR range -180...+180 converted to 0...360 R
instCVal.mag.f deadbanded
instCVal.ang.f deadbanded
5, the code for primary amperes
0, the code for a multiplier of 1
current cut-off level.
UR range -180...+180 converted to 0...360 R
instCVal.mag.f deadbanded
instCVal.ang.f deadbanded
5, the code for primary amperes
0, the code for a multiplier of 1
UR FAMILY – COMMUNICATIONS GUIDE
R/W/C
R
R
R
R
R/W/C
R/W/C
R
R
R
R
R
R
R
R
R
R
R/W/C
R/W/C
R
R
R
R
R
R
R
R
R
R
R/W/C
R/W/C
R
R
R
R
R
R
R
R
R
R
R/W/C
R/W/C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents