MEMORY MAP
Products
Address Register name
"
6888
"
6889
"
688A
"
688B
"
688C
"
688D
2
"
688E
"
688F
"
6890
"
6891
"
6893
"
6894
"
6895
"
6897
"
6899
"
689B
Pilot Directional Comparison Unblocking (DCUB) Scheme (Read/Write Setting)
D60, L90
68A0
"
68A1
"
68A3
"
68A4
"
68A6
"
68A8
"
68AA
"
68AB
"
68AC
"
68AD
"
68AE
"
68AF
"
68B0
"
68B1
"
68B2
"
68B3
"
68B4
"
68B6
"
68B8
"
68BA
"
68BC
"
68BE
2-96
Autoreclose Transfer 2 to 1
Autoreclose Breaker 1 Fail Option
Autoreclose Breaker 2 Fail Option
Autoreclose 1P Dead Time
Autoreclose Breaker Sequence
Autoreclose Transfer Time
Autoreclose Event
Autoreclose 3P Dead Time 3
Autoreclose 3P Dead Time 4
Autoreclose Bus Fault Initiate
Autoreclose Initiate Mode
Autoreclose Mode Aut
Autoreclose Mode 1 Activation
Autoreclose Mode 2 Activation
Autoreclose Mode 3 Activation
Autoreclose Mode 4 Activation
Directional Comparison Unblocking
Scheme Function
Directional Comparison Unblocking Block
Directional Comparison Unblocking
Permissive Echo
Directional Comparison Unblocking Echo
Condition
DCUB Ground Directional Overcurrent
Forward
DCUB Ground Directional Overcurrent
Reverse
DCUB Transmit Block Pickup Delay
DCUB Transmit Block Reset Delay
Directional Comparison Unblocking Echo
Duration
Directional Comparison Unblocking Echo
Lockout
DCUB Line End Open Pickup Delay
DCUB Loss-of-Guard (Log) Pickup Delay
DCUB Guard Healthy Reset Delay
DCUB Loss-of-Guard Trip Window
Directional Comparison Unblocking Seal-In
Delay
Directional Comparison Unblocking
Communication Bits
Directional Comparison Unblocking Rx1
Directional Comparison Unblocking Log1
Directional Comparison Unblocking Rx2
Directional Comparison Unblocking Log2
Directional Comparison Unblocking Rx3
Directional Comparison Unblocking Log3
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 655.35
s
0.01
0 to 4
---
1
0 to 655.35
s
0.01
0 to 1
---
1
0 to 655.35
s
0.01
0 to 655.35
s
0.01
0 to 4294967295
---
1
0 to 1
---
1
0 to 3
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 2
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 2
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
UR FAMILY – COMMUNICATIONS GUIDE
Format
Default
F126
0 (No)
F081
0 (Continue)
F081
0 (Continue)
F001
100
F082
3 (1 - 2)
F001
400
F102
0 (Disabled)
F001
200
F001
400
F300
0
F610
0 (Protection
AND CB)
F622
0 (Mode 1 (1
& 3 Pole))
F300
0
F300
0
F300
0
F300
0
F102
0 (Disabled)
F300
0
F199
0 (Disabled)
F300
0
F300
0
F300
0
20
90
100
250
50
8
15
150
10
F198
0 (1 bit)
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0