CHAPTER 3: IEC 61850 COMMUNICATION
LNName: RRTDsSTMP#
data obj. data attribute
Type
stVal
BOOLEAN
Dpo
SPS
stVal
BOOLEAN
DpoAlm
SPS
stVal
BOOLEAN
OpnCirc
SPS
stVal
BOOLEAN
ShrtCirc
SPS
stVal
BOOLEAN
Tmp
MV
instMag
AnalogueValue
instMag.f
FLOAT32
mag
AnalogueValue
mag.f
FLOAT32
units
Unit
units.SIUnit
ENUMERATED
units.multiplier
ENUMERATED
db
INT32U
zeroDb
INT32U
BlkRef1
ORG
GEORG
setSrcRef
ObjectReference SP
VISIBLE
STRING255
setSrcCB
ObjectReference SP
VISIBLE
STRING255
cdcNs
VISIBLE
STRING255
cdcName
VISIBLE
STRING255
3.5.2.67 Sensitive directional power (Sen)
This element is instantiated in the following products: C60, D60, F60, G30, G60, L90, M60, N60, T60.
Table 3-112: Sensitive directional power general data objects
LNName: SenPDOP#
data obj. data attribute
Type
Str
ACD
general
BOOLEAN
dirGeneral
ENUMERATED
Op
ACT
general
BOOLEAN
Dpo
SPS
stVal
BOOLEAN
UR FAMILY – COMMUNICATIONS GUIDE
LDevice inst: Prot
UR element: RRTD Input #
FC UR Name
ST
RRTD RTD # ALARM OP
ST
RRTD RTD # TRIP DPO
ST
RRTD RTD # ALARM DPO
ST
RRTD RTD # OPEN
ST
RRTD RTD # SHORTED
MX
RRTD INPUT #
MX
CF
CF
RRTDsSTMP#.Tmp.db
CF
RRTD # BLOCK.
SP
Reference to the ultimate source
of value selected by setting
RRTD # BLOCK.
SP
If reference is external to this
IED, mapped to the source's
GOOSE control block, else empty
string
EX
Name of the GE Multilin
namespace at the time of this
firmware release
EX
GEORG
LDevice inst: Prot
UR element: Sensitive Directional Power element # core functions
FC UR Name
ST
DIR POWER # PKP
ST
ST
DIR POWER # OP
ST
DIR POWER # DPO
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Description
RRTD RTD # TRIP DPO operand
RRTD RTD # ALARM DPO operand
RRTD RTD # OPEN operand
RRTD RTD # SHORTED operand
RRTD INPUT # Temperature in degree
Celsius
instMag.f deadbanded
23
0
0
RRTD # BLOCK setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
Description
DIR POWER # PKP operand, which
becomes On when either stage 1 or stage
2 of this element has picked up.
0, the code for unknown. It is unknown as
the element may be connected/
configured to look forward or backward
DIR POWER # OP operand
DIR POWER # DPO operand, which is the
inverse of DIR POWER OP
R/W/C
R
R
R
R
R
R
R
R
R
R
R
3
R
R
R
R
R
R
R/W/C
R
R
R
R/C
R/C
R/C
R/C
R
R
R/W/C
R
R
R
R
R
R
R