CHAPTER 3: IEC 61850 COMMUNICATION
LNName: Rec13pRREC1
data obj. data attribute
Type
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef12
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef13
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef14
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef15
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
BlkRef1
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef17
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
BlkRef3
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRef19
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
3.5.3.23 Synchrocheck (SynChk)
This element is instantiated in the following products: C60, D30, D60, F60, G30, G60, L30, L60, L90, N60, T60.
Table 3-160: Synchrocheck data objects
LNName: SynChkRSYN#
data obj. data attribute
Type
Mod
INC
stVal
ENUMERATED
ctlModel
CtlModels
Health
INS
stVal
ENUMERATED
Rel
SPS
stVal
BOOLEAN
RelDpo
SPS
stVal
BOOLEAN
LivV1
SPS
stVal
BOOLEAN
DeaV1
SPS
UR FAMILY – COMMUNICATIONS GUIDE
LDevice inst: Ctrl
UR element: Autoreclose element
FC UR Name
BKR ONE POLE OPEN setting
BKR 3 POLE OPEN setting
AR EXTEND DEAD T 1setting
AR RESET setting
AR BKR CLOSED setting
AR BLOCK.
AR PAUSE setting
AR BLOCK BKR2 setting
AR BUS FLT INIT setting
LDevice inst: Ctrl
UR element: Synchrocheck element # (ANSI 25)
FC UR Name
ST
CF
ST
LPHD1.PhyHealth.stVal
ST
SYNC # CLS OP
ST
SYNC # CLS DPO
ST
SYNC # V1 ABOVE MIN
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Description
reference to the data attribute to input
source GoCB of input if via GOOSE
BKR 3 POLE OPEN setting
reference to the data attribute to input
source GoCB of input if via GOOSE
AR EXTEND DEAD T 1 setting
reference to the data attribute to input
source GoCB of input if via GOOSE
AR RESET setting
reference to the data attribute to input
source GoCB of input if via GOOSE
AR BKR CLOSED setting
reference to the data attribute to input
source GoCB of input if via GOOSE
AR BLOCK setting
reference to the data attribute to input
source GoCB of input if via GOOSE
AR PAUSE setting
reference to the data attribute to input
source GoCB of input if via GOOSE
AR BLOCK BKR2 setting
reference to the data attribute to input
source GoCB of input if via GOOSE
AR BUS FLT INIT setting
reference to the data attribute to input
source GoCB of input if via GOOSE
Description
This logical node's mode
1 (on)
0 (status only)
This logical node's health
SYNC # CLS OP operand, which becomes
On all synchrocheck criteria are fulfilled.
SYNC # CLS DPO operand, which
becomes Off when all synchrocheck
criteria are fulfilled.
SYNC # V1 ABOVE MIN operand, which
indicates that V1 is above the LivVal1
setting.
SYNC # V1 BELOW MAX operand, which
indicates that V1 is below the DeaVal1
setting.
R/W/C
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
3
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R/W/C
R/Ctrl
R
R
R
R
R
R
R
R
R
R
R
3-141