Basic Setting
Basic setting includes address and device name. Address should be the same with the address
set by DIP switch at the rear panel of the device, which ranges from 1~15. Please refer to the
chapter "Address Setting" for related device setting. Device name can be renamed by users and
note that don't create the same name in one project.
Speaker Lines
Speaker Lines is used to enable speaker lines. Click the checkbox as below,
enabled and
means disabled. Users can change the name and power of speaker lines. The
load power is only used to note.
Selecting a speaker line and clicking the
the current one
Trigger Mode of Dry Contact Inputs
This table is used to set the trigger mode of each dry contact input as Normally Open or
Normally Closed.
If "Normally Open" is selected, when the switch of third party device is opened, the dry contact
input will be deactivated, and when the switch is closed, the dry contact will be activated.
If "Normally Closed" is selected, when the switch of third party device is closed, the dry contact
input will be deactivated, and when the switch is opened, the dry contact will be activated.
2.
Amplifier
Set the model of power amplifier corresponding to each audio channel, then set the ports of RK-
ZONE24 which are connected to the output of power amplifier. The setting must be same with
the actual connection.
When the amplifier redundancy function is needed, if the audio signal of spare power amplifier
is from this device, set the model of power amplifier in the Spare row, then set the spare ports
of the devices which are connected to the output of the spare power amplifier.
In the Backup Amplifier column, select the spare amplifier corresponding to the main amplifiers
to enable the redundancy function.
button can set all the power to be the same with