Honeywell INTEVIO User Manual page 16

Pa/va system
Table of Contents

Advertisement

Rear Panel
No.
Parts/Ports
1
Audio output of CH1
2
Audio output of CH2
3
REC output
4
AUX1/AUX2
5
MIC/LINE input
6
MIC/LINE DIP switch
Power amplifier
7
interface
Spare power amplifier
8
interface
9
Call station interface
10
Power switch
11
Main power & fuse
12
Dry contact outputs
13
Contact inputs
Description
To enable a signal output to channel 1.This can be connected
to an external power amplifier or third-party devices.
To enable the signal output to channel 2. This can be
connected to an external power amplifier or third-party devices.
To output the audio signal from a microphone. This can be
connected to an external recording device.
To be connected with an optional external audio source, such
as CD/DVD player, tuner, etc.
It is a balanced input and can be connected with an external
microphone or other audio devices. The input sensitivity can be
set via the DIP switch.
To set the sensitivity and the phantom power output of the
MIC/LINE input.
To connect to the external power amplifiers of two audio
channels, the MCU will transmit the audio signal and self-test
signal to the power amplifier(s) and receive the fault status from
power amplifier(s).
To connect to a spare power amplifier, the MCU will transmit
the audio signal and self-test signal to power amplifier and
receive the fault status from power amplifier.
To connect to the remote call station, transmit audio signals,
control data, and enable the power supply from the MCU to
remote call stations.
To turn on or turn off the AC power.
To connect to the AC power supply. A fuse must be installed in
the socket for over current protection.
8 dry contact output interfaces, which can be used to control
external devices.
10 contact input interfaces, which can be connected to the third-
party devices for the business or voice alarm purpose.
8