Installing The Remote Call Station In Cabinet; Flush Installation Of A Remote Call Station - Honeywell INTEVIO User Manual

Pa/va system
Table of Contents

Advertisement

Installing the Remote Call Station in Cabinet

Follow above procedures to connect the remote call station and key modules, then install the call
station to the fixed bracket as following steps:
1.Place the remote call station in the frame.
2.With the call station in place, turn the bracket over. Use the screws provided to fasten the call
station to the bracket.
3.Place the bracket/call station assembly in the cabinet and use the hardware provided to fasten it.
4.Install the PTT microphone to the RK-MIC socket and hang the microphone in the space provided
on the left side of the rack.

Flush Installation of a Remote Call Station

To flush mount the installation of the RK-MIC, use the dimensions below to create the opening to
install the call station.
The 192 mm x 192 mm section of the above stated dimensions is for the flush installation of the
remote call station only. For key modules, expand the length by 100 mm for each module.
The diameter of cable should be less than 20 mm. Ensure that there is enough space to
accommodate the wiring and connections.