Using the Performance Monitoring Screen
Procedure: Select Signal-Type Menus on the Performance Monitoring Screen
Open the electrical or optical card of choice. Double-click the card graphic in the main (node) view or
Step 1
right-click the card and select Open Card. (Clicking a card once highlights the card only.)
From the card view, click the Performance tab.
Step 2
Click the signal-type menu. (For example, the OC48 card has a menu labeled STS.)
Step 3
Select a port using the signal-type menu.
Step 4

8.1.5 Using the Baseline Button

In Software R3.0 and higher, the Baseline button located on the far right of the screen clears the PM
count displayed in the Current column, but does not clear the PM count on the card. The value is changed
in the CTC software, but is not changed for the NE. When the current 15-minute or 24-hour time interval
expires or the screen view changes, the total number of PM counts on the card and on the screen appear
in the appropriate column, decrementing from the values at the time the command is performed.
The baseline values are discarded if you select a new port, interval, near-end, far-end, STS, or if you
change views to a different screen and then return to the Performance Monitoring screen. The Baseline
button enables you to easily see how quickly PM counts are rising without having to perform
calculations.
Figure 8-5
Cisco ONS 15327 User Documentation, R3.3
8-8
Figure 8-5
shows the Baseline button on the Performance Monitoring screen.
Baseline button for clearing displayed PM counts
Chapter 8
Performance Monitoring
Baseline button